Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2011
Principal Product Transceiver
NAICS 334220 - Radio and Television Broadcasting and Wireless Communications Equipment Manufacturing
SIC 3663 - Radio & Tv Communications Equipment
Sales $10,000,000-$50,000,000
# of Employees 180
Plant Area (Sq.Ft.) 57,000
Annual Production 10,000 Pieces
Production Hrs. Annual 2,295
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $95,155 1,678,680 kWh $0.06
Electricity Demand $64,360 11,354 kW-months/year $5.67
TOTAL ENERGY COSTS $159,515
RECOMMENDED SAVINGS* $42,135 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $33,729
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD Savings:
$16,812
Cost:
$34,688
$11,020 122,442 $5,792 640 $11,020
122,442
kWh
$5,792
640
kW-months/year
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$11,265
Cost:
$2,500
$7,383 82,036 $3,882 429 $7,383
82,036
kWh
$3,882
429
kW-months/year
03: 2.7496 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE Savings:
$8,406
Cost:
$12,400
$5,510 61,221 $2,896 320 $5,510
61,221
kWh
$2,896
320
kW-months/year
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,489
Cost:
$5,225
$2,285 25,389 $1,204 133 $2,285
25,389
kWh
$1,204
133
kW-months/year
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,157
Cost:
$50
$918 10,196 $239 26 $918
10,196
kWh
$239
26
kW-months/year
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,006
Cost:
$1,320
$804 8,927 $202 113 $804
8,927
kWh
$202
113
kW-months/year
TOTAL RECOMMENDED Savings:
$42,135
Cost:
$56,183
$27,920 310,211 $14,215 1,661 $27,920
310,211
kWh
$14,215
1,661
kW-months/year
TOTAL IMPLEMENTED Savings:
$33,729
Cost:
$43,783
$22,410 248,990 $11,319 1,341 $22,410
248,990
kWh
$11,319
1,341
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand