Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2011
Principal Product Fruit Juice
NAICS 311411 - Frozen Fruit, Juice, and Vegetable Manufacturing
SIC 2037 - Frozen Fruits And Vegetables
Sales $100,000,000-$500,000,000
# of Employees 740
Plant Area (Sq.Ft.) 1,000,000
Annual Production 80,000 Thousand Gallons
Production Hrs. Annual 8,568
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $4,666,822 77,902,497 kWh $0.06
Electricity Demand $173,576 134,837 kW-months/year $1.29
Natural Gas $3,550,432 674,530 MMBtu $5.26
TOTAL ENERGY COSTS $8,390,830
RECOMMENDED SAVINGS* $258,520 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $83,606
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$64,568
Cost:
$175,700
$62,955 912,388 $1,613 1,253 - - $62,955
912,388
kWh
$1,613
1,253
kW-months/year
-
-
MMBtu
02: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$39,559
Cost:
$7,338
$38,190 553,480 $1,369 1,064 - - $38,190
553,480
kWh
$1,369
1,064
kW-months/year
-
-
MMBtu
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$24,805
Cost:
$1,320
$23,727 343,875 $1,078 838 - - $23,727
343,875
kWh
$1,078
838
kW-months/year
-
-
MMBtu
04: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$20,342
Cost:
$1,350
- - - - $20,342 3,860 -
-
kWh
-
-
kW-months/year
$20,342
3,860
MMBtu
05: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$18,730
Cost:
$26,000
- - - - $18,730 3,554 -
-
kWh
-
-
kW-months/year
$18,730
3,554
MMBtu
06: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD Savings:
$18,125
Cost:
$133,000
$15,370 222,754 $2,755 2,141 - - $15,370
222,754
kWh
$2,755
2,141
kW-months/year
-
-
MMBtu
07: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$17,851
Cost:
$20,000
$17,406 252,312 $445 346 - - $17,406
252,312
kWh
$445
346
kW-months/year
-
-
MMBtu
08: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$16,463
Cost:
$16,554
- - - - $16,463 3,124 -
-
kWh
-
-
kW-months/year
$16,463
3,124
MMBtu
09: 2.2447 HEAT WATER WITH EXHAUST HEAT Savings:
$16,131
Cost:
$30,000
- - - - $16,131 3,061 -
-
kWh
-
-
kW-months/year
$16,131
3,061
MMBtu
10: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$8,346
Cost:
$10,000
$8,138 117,936 $208 162 - - $8,138
117,936
kWh
$208
162
kW-months/year
-
-
MMBtu
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$8,145
Cost:
$8,889
$7,942 115,097 $203 158 - - $7,942
115,097
kWh
$203
158
kW-months/year
-
-
MMBtu
12: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$5,455
Cost:
$2,425
$5,375 77,903 $80 62 - - $5,375
77,903
kWh
$80
62
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$258,520
Cost:
$432,576
$179,103 2,595,745 $7,751 6,024 $71,666 13,599 $179,103
2,595,745
kWh
$7,751
6,024
kW-months/year
$71,666
13,599
MMBtu
TOTAL IMPLEMENTED Savings:
$83,606
Cost:
$181,634
$60,552 877,565 $4,324 3,361 $18,730 3,554 $60,552
877,565
kWh
$4,324
3,361
kW-months/year
$18,730
3,554
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas