Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2013 |
Principal Product | Surgical appliances and supplies |
NAICS | 339113 - Surgical Appliance and Supplies Manufacturing |
SIC | 3842 - Surgical Appliances And Supplies |
Sales | $100,000,000-$500,000,000 |
# of Employees | 320 |
Plant Area (Sq.Ft.) | 67,000 |
Annual Production | 45 Pieces |
Production Hrs. Annual | 2,080 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $84,555 | 1,533,650 | kWh | $0.06 |
Electricity Demand | $47,086 | 4,702 | kW-months/year | $10.01 |
Electricity Fees | $32,831 | - | $ | - |
TOTAL ENERGY COSTS | $164,472 | |||
RECOMMENDED SAVINGS* | $59,009 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $55,394 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $16,509 Cost: $3,900 |
$13,204 | 240,068 | $3,305 | 330 |
$13,204 240,068 kWh |
$3,305 330 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $11,217 Cost: $6,000 |
$5,449 | 99,856 | $5,768 | 576 |
$5,449 99,856 kWh |
$5,768 576 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $9,040 Cost: $80 |
$5,845 | 106,271 | $3,195 | 319 |
$5,845 106,271 kWh |
$3,195 319 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $7,960 Cost: $540 |
$6,368 | 115,789 | $1,592 | 159 |
$6,368 115,789 kWh |
$1,592 159 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $3,883 Cost: $4,691 |
$2,798 | 50,874 | $1,085 | 108 |
$2,798 50,874 kWh |
$1,085 108 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $2,564 Cost: $440 |
$570 | 10,356 | $1,994 | 199 |
$570 10,356 kWh |
$1,994 199 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $2,118 Cost: $5,397 |
$1,367 | 24,856 | $751 | 75 |
$1,367 24,856 kWh |
$751 75 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $1,942 Cost: $2,196 |
$947 | 17,233 | $995 | 99 |
$947 17,233 kWh |
$995 99 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,593 Cost: $1,660 |
$1,528 | 27,788 | $65 | 6 |
$1,528 27,788 kWh |
$65 6 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $955 Cost: $80 |
$694 | 12,615 | $261 | 26 |
$694 12,615 kWh |
$261 26 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $686 Cost: $1,520 |
$336 | 6,112 | $350 | 35 |
$336 6,112 kWh |
$350 35 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $542 Cost: $209 |
$262 | 4,766 | $280 | 28 |
$262 4,766 kWh |
$280 28 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $59,009 Cost: $26,713 |
$39,368 | 716,584 | $19,641 | 1,960 | $39,368 716,584 kWh |
$19,641 1,960 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $55,394 Cost: $21,027 |
$37,045 | 674,347 | $18,349 | 1,831 | $37,045 674,347 kWh |
$18,349 1,831 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand |