Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2013 |
Principal Product | Aircraft and heavy repair services |
NAICS | 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Main |
SIC | 7699 - Repair Services, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 168 |
Plant Area (Sq.Ft.) | 85,000 |
Annual Production | 6,000 Pieces |
Production Hrs. Annual | 3,432 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $111,936 | 2,316,485 | kWh | $0.05 |
Electricity Demand | $142,844 | 12,568 | kW-months/year | $11.37 |
Electricity Fees | $65,697 | - | $ | - |
TOTAL ENERGY COSTS | $320,477 | |||
RECOMMENDED SAVINGS* | $70,857 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $56,067 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $24,158 Cost: $2,300 |
$18,405 | 368,102 | $5,753 | 506 |
$18,405 368,102 kWh |
$5,753 506 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $13,601 Cost: $80 |
$7,641 | 152,815 | $5,960 | 540 |
$7,641 152,815 kWh |
$5,960 540 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $8,984 Cost: $19,999 |
$5,004 | 100,082 | $3,980 | 350 |
$5,004 100,082 kWh |
$3,980 350 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $7,171 Cost: $9,782 |
$3,999 | 79,976 | $3,172 | 279 |
$3,999 79,976 kWh |
$3,172 279 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,219 Cost: $1,660 |
$2,899 | 57,974 | $2,320 | 204 |
$2,899 57,974 kWh |
$2,320 204 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $3,831 Cost: $440 |
$2,137 | 42,749 | $1,694 | 149 |
$2,137 42,749 kWh |
$1,694 149 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $2,047 Cost: $10,080 |
$1,558 | 31,158 | $489 | 43 |
$1,558 31,158 kWh |
$489 43 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,653 Cost: $80 |
$142 | 2,859 | $1,511 | 133 |
$142 2,859 kWh |
$1,511 133 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.6127 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT |
Savings: $1,638 Cost: $793 |
$910 | 18,200 | $728 | 64 |
$910 18,200 kWh |
$728 64 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,228 Cost: $417 |
$682 | 13,624 | $546 | 48 |
$682 13,624 kWh |
$546 48 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $814 Cost: $2,255 |
$359 | 7,172 | $455 | 40 |
$359 7,172 kWh |
$455 40 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7496 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE |
Savings: $513 Cost: $1,128 |
$286 | 5,719 | $227 | 20 |
$286 5,719 kWh |
$227 20 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $70,857 Cost: $49,014 |
$44,022 | 880,430 | $26,835 | 2,376 | $44,022 880,430 kWh |
$26,835 2,376 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $56,067 Cost: $27,167 |
$35,360 | 707,204 | $20,707 | 1,837 | $35,360 707,204 kWh |
$20,707 1,837 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand |