IAC logo
IAC Assessment: MI0255
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MI0255
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2014
Principal Product Steel Products
NAICS 325412 - Pharmaceutical Preparation Manufacturing
SIC 2834 - Pharmaceutical Preparations
Sales $10,000,000-$50,000,000
# of Employees 48
Plant Area (Sq.Ft.) 94,000
Annual Production 12,000 Tons
Production Hrs. Annual 4,420
Location (State) PR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $103,693 470,989 kWh $0.22
Electricity Demand $34,677 3,001 kW-months/year $11.56
Electricity Fees $5,400 - $ -
TOTAL ENERGY COSTS $143,770
RECOMMENDED SAVINGS* $50,716 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $32,916
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$9,165
Cost:
$1,800
$8,021 36,457 $1,144 99 $8,021
36,457
kWh
$1,144
99
kW-months/year
02: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$8,786
Cost:
$800
- - $8,786 760 -
-
kWh
$8,786
760
kW-months/year
03: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT Savings:
$6,657
Cost:
$40
$5,178 23,536 $1,479 128 $5,178
23,536
kWh
$1,479
128
kW-months/year
04: 2.7145 INSTALL SKYLIGHTS Savings:
$5,547
Cost:
$1,340
$4,854 22,065 $693 60 $4,854
22,065
kWh
$693
60
kW-months/year
05: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$5,455
Cost:
$5,293
$4,774 21,704 $681 59 $4,774
21,704
kWh
$681
59
kW-months/year
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,662
Cost:
$3,500
$4,084 18,564 $578 50 $4,084
18,564
kWh
$578
50
kW-months/year
07: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$3,969
Cost:
$80
$3,472 15,781 $497 43 $3,472
15,781
kWh
$497
43
kW-months/year
08: 2.7493 USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES Savings:
$2,136
Cost:
$1,175
$1,870 8,502 $266 23 $1,870
8,502
kWh
$266
23
kW-months/year
09: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,951
Cost:
$1,660
$1,771 8,051 $180 16 $1,771
8,051
kWh
$180
16
kW-months/year
10: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,364
Cost:
$80
$1,037 4,713 $327 28 $1,037
4,713
kWh
$327
28
kW-months/year
11: 2.6127 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT Savings:
$1,024
Cost:
$347
$897 4,076 $127 11 $897
4,076
kWh
$127
11
kW-months/year
TOTAL RECOMMENDED Savings:
$50,716
Cost:
$16,115
$35,958 163,449 $14,758 1,277 $35,958
163,449
kWh
$14,758
1,277
kW-months/year
TOTAL IMPLEMENTED Savings:
$32,916
Cost:
$4,807
$20,376 92,614 $12,540 1,085 $20,376
92,614
kWh
$12,540
1,085
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand