IAC logo
IAC Assessment: MI0256
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MI0256
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2014
Principal Product Pharmacutical
NAICS 325412 - Pharmaceutical Preparation Manufacturing
SIC 2834 - Pharmaceutical Preparations
Sales $10,000,000-$50,000,000
# of Employees 55
Plant Area (Sq.Ft.) 50,000
Annual Production 1,000,000 Pieces
Production Hrs. Annual 3,744
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $207,693 4,863,600 kWh $0.04
Electricity Demand $110,630 8,153 kW-months/year $13.57
Electricity Fees $45,000 - $ -
Natural Gas $78,473 12,016 MMBtu $6.53
TOTAL ENERGY COSTS $441,797
RECOMMENDED SAVINGS* $110,569 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $80,495
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$23,834
Cost:
$20,160
$16,628 386,703 $7,206 531 - - $16,628
386,703
kWh
$7,206
531
kW-months/year
-
-
MMBtu
02: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD Savings:
$23,626
Cost:
$13,599
$16,495 383,601 $7,131 525 - - $16,495
383,601
kWh
$7,131
525
kW-months/year
-
-
MMBtu
03: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$23,619
Cost:
$80
$16,495 383,601 $7,124 525 - - $16,495
383,601
kWh
$7,124
525
kW-months/year
-
-
MMBtu
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$14,420
Cost:
$1,660
$8,698 202,273 $5,722 421 - - $8,698
202,273
kWh
$5,722
421
kW-months/year
-
-
MMBtu
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$11,196
Cost:
$3,960
- - - - $11,196 1,714 -
-
kWh
-
-
kW-months/year
$11,196
1,714
MMBtu
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$7,634
Cost:
$80
$3,571 83,057 $4,063 300 - - $3,571
83,057
kWh
$4,063
300
kW-months/year
-
-
MMBtu
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$3,540
Cost:
$3,240
$2,468 57,346 $1,072 79 - - $2,468
57,346
kWh
$1,072
79
kW-months/year
-
-
MMBtu
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,517
Cost:
$3,360
$811 18,870 $706 52 - - $811
18,870
kWh
$706
52
kW-months/year
-
-
MMBtu
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,183
Cost:
$6,800
$586 13,628 $597 44 - - $586
13,628
kWh
$597
44
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$110,569
Cost:
$52,939
$65,752 1,529,079 $33,621 2,477 $11,196 1,714 $65,752
1,529,079
kWh
$33,621
2,477
kW-months/year
$11,196
1,714
MMBtu
TOTAL IMPLEMENTED Savings:
$80,495
Cost:
$19,379
$45,259 1,052,532 $24,040 1,771 $11,196 1,714 $45,259
1,052,532
kWh
$24,040
1,771
kW-months/year
$11,196
1,714
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas