Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2014
Principal Product Fruit Juice
NAICS 311411 - Frozen Fruit, Juice, and Vegetable Manufacturing
SIC 2037 - Frozen Fruits And Vegetables
Sales $10,000,000-$50,000,000
# of Employees 85
Plant Area (Sq.Ft.) 200,000
Annual Production 1,500,000 Pieces
Production Hrs. Annual 5,616
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $327,181 3,531,240 kWh $0.09
Electricity Demand $93,198 12,897 kW-months/year $7.23
Electricity Fees $24,189 - $ -
Natural Gas $75,906 9,035 MMBtu $8.40
TOTAL ENERGY COSTS $520,474
RECOMMENDED SAVINGS* $71,008 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $20,319
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$23,147
Cost:
$3,600
$19,852 213,460 $3,295 456 - - - - $19,852
213,460
kWh
$3,295
456
kW-months/year
-
-
MMBtu
-
-
$
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$11,051
Cost:
$500
$9,830 105,700 $1,221 169 - - - - $9,830
105,700
kWh
$1,221
169
kW-months/year
-
-
MMBtu
-
-
$
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$13,762
Cost:
$28,000
- - - - $13,762 1,638 - - -
-
kWh
-
-
kW-months/year
$13,762
1,638
MMBtu
-
-
$
04: 2.2447 HEAT WATER WITH EXHAUST HEAT Savings:
$6,564
Cost:
$8,859
- - - - $6,564 781 - - -
-
kWh
-
-
kW-months/year
$6,564
781
MMBtu
-
-
$
05: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING Savings:
$4,131
Cost:
$4,980
$3,543 38,091 $588 81 - - - - $3,543
38,091
kWh
$588
81
kW-months/year
-
-
MMBtu
-
-
$
06: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) Savings:
$3,052
Cost:
$560
- - - - - - $3,052 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$3,052
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,377
Cost:
$10,770
$2,037 21,902 $340 47 - - - - $2,037
21,902
kWh
$340
47
kW-months/year
-
-
MMBtu
-
-
$
08: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,643
Cost:
$497
$1,412 15,181 $231 32 - - - - $1,412
15,181
kWh
$231
32
kW-months/year
-
-
MMBtu
-
-
$
09: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,472
Cost:
$1,660
$1,305 14,032 $167 23 - - - - $1,305
14,032
kWh
$167
23
kW-months/year
-
-
MMBtu
-
-
$
10: 2.2515 USE OPTIMUM THICKNESS INSULATION Savings:
$1,375
Cost:
$360
- - - - $1,375 163 - - -
-
kWh
-
-
kW-months/year
$1,375
163
MMBtu
-
-
$
11: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,317
Cost:
$80
$1,120 12,047 $197 27 - - - - $1,120
12,047
kWh
$197
27
kW-months/year
-
-
MMBtu
-
-
$
12: 2.2511 INSULATE BARE EQUIPMENT Savings:
$708
Cost:
$280
$607 6,526 $101 14 - - - - $607
6,526
kWh
$101
14
kW-months/year
-
-
MMBtu
-
-
$
13: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$409
Cost:
$173
$351 3,774 $58 8 - - - - $351
3,774
kWh
$58
8
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$71,008
Cost:
$60,319
$40,057 430,713 $6,198 857 $21,701 2,582 $3,052 - $40,057
430,713
kWh
$6,198
857
kW-months/year
$21,701
2,582
MMBtu
$3,052
-
$
TOTAL IMPLEMENTED Savings:
$20,319
Cost:
$3,830
$14,018 150,734 $1,874 259 $1,375 163 $3,052 - $14,018
150,734
kWh
$1,874
259
kW-months/year
$1,375
163
MMBtu
$3,052
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes