Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2016 |
Principal Product | Automotive parts |
NAICS | 336390 - Other Motor Vehicle Parts Manufacturing |
SIC | 3714 - Motor Vehicle Parts And Accessories |
Sales | $50,000,000-$100,000,000 |
# of Employees | 130 |
Plant Area (Sq.Ft.) | 250,000 |
Annual Production | 44,400,000 Pieces |
Production Hrs. Annual | 6,000 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $332,783 | 5,460,000 | kWh | $0.06 |
Electricity Demand | $152,624 | 12,240 | kW-months/year | $12.47 |
Electricity Fees | $38,159 | - | $ | - |
Natural Gas | $17,722 | 1,555 | MMBtu | $11.39 |
TOTAL ENERGY COSTS | $541,289 | |||
RECOMMENDED SAVINGS* | $341,665 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $67,406 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $97,105 Cost: $82,600 |
$146,274 | 2,397,928 | $59,801 | 4,796 | $(-108,970) | (-9,563) | - | - |
$146,274 2,397,928 kWh |
$59,801 4,796 kW-months/year |
$(-108,970) (-9,563) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $65,063 Cost: $200,000 |
$30,534 | 500,551 | $8,529 | 684 | - | - | $26,000 | - |
$30,534 500,551 kWh |
$8,529 684 kW-months/year |
- - MMBtu |
$26,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $40,957 Cost: $1,120 |
$40,957 | 671,420 | - | - | - | - | - | - |
$40,957 671,420 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $27,925 Cost: $1,400 |
$19,820 | 324,921 | $8,105 | 650 | - | - | - | - |
$19,820 324,921 kWh |
$8,105 650 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $23,144 Cost: $7,000 |
$16,411 | 269,029 | $6,733 | 538 | - | - | - | - |
$16,411 269,029 kWh |
$6,733 538 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $21,747 Cost: $40 |
$15,438 | 253,076 | $6,309 | 506 | - | - | - | - |
$15,438 253,076 kWh |
$6,309 506 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7496 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE |
Savings: $21,352 Cost: $22,281 |
$21,352 | 350,035 | - | - | - | - | - | - |
$21,352 350,035 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $21,133 Cost: $1,660 |
$17,946 | 294,189 | $3,187 | 256 | - | - | - | - |
$17,946 294,189 kWh |
$3,187 256 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $9,631 Cost: $16,156 |
$6,165 | 101,073 | $3,466 | 278 | - | - | - | - |
$6,165 101,073 kWh |
$3,466 278 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $5,934 Cost: $10,031 |
$4,212 | 69,053 | $1,722 | 138 | - | - | - | - |
$4,212 69,053 kWh |
$1,722 138 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $5,116 Cost: $884 |
$5,116 | 83,862 | - | - | - | - | - | - |
$5,116 83,862 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,442 Cost: $2,628 |
$1,442 | 23,638 | - | - | - | - | - | - |
$1,442 23,638 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $781 Cost: $240 |
$781 | 12,000 | - | - | - | - | - | - |
$781 12,000 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $335 Cost: $944 |
$208 | 3,407 | $127 | 10 | - | - | - | - |
$208 3,407 kWh |
$127 10 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $341,665 Cost: $346,984 |
$326,656 | 5,354,182 | $97,979 | 7,856 | $(-108,970) | (-9,563) | $26,000 | - | $326,656 5,354,182 kWh |
$97,979 7,856 kW-months/year |
$(-108,970) (-9,563) MMBtu |
$26,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $67,406 Cost: $34,513 |
$57,359 | 940,298 | $10,047 | 804 | - | - | - | - | $57,359 940,298 kWh |
$10,047 804 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes |