Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2016 |
Principal Product | Solid Dosage Pharmaceuticals |
NAICS | 325412 - Pharmaceutical Preparation Manufacturing |
SIC | 2834 - Pharmaceutical Preparations |
Sales | $10,000,000-$50,000,000 |
# of Employees | 80 |
Plant Area (Sq.Ft.) | 136,000 |
Annual Production | 120 Units |
Production Hrs. Annual | 4,160 |
Location (State) | PR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,580,135 | 10,066,672 | kWh | $0.16 |
Electricity Demand | $152,665 | 17,580 | kW-months/year | $8.68 |
Electricity Fees | $42,929 | - | $ | - |
LPG | $158,579 | 9,669 | MMBtu | $16.40 |
TOTAL ENERGY COSTS | $1,934,308 | |||
RECOMMENDED SAVINGS* | $530,595 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $329,104 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Administrative Changes | Electricity Usage | Electricity Demand | LPG | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $98,547 Cost: $35,359 |
$85,547 | 544,884 | $13,000 | 1,497 | - | - | - | - |
$85,547 544,884 kWh |
$13,000 1,497 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS |
Savings: $96,255 Cost: $386 |
$89,475 | 569,907 | $6,780 | 781 | - | - | - | - |
$89,475 569,907 kWh |
$6,780 781 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $75,921 Cost: $15,156 |
$65,474 | 417,034 | $10,447 | 1,203 | - | - | - | - |
$65,474 417,034 kWh |
$10,447 1,203 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $68,863 Cost: $173 |
$68,863 | 438,616 | - | - | - | - | - | - |
$68,863 438,616 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $47,043 Cost: $12,140 |
$39,123 | 249,194 | $7,920 | 912 | - | - | - | - |
$39,123 249,194 kWh |
$7,920 912 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.8123 PAY UTILITY BILLS ON TIME |
Savings: $37,529 Cost: - |
- | - | - | - | - | - | $37,529 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$37,529 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $23,599 Cost: $40 |
$21,827 | 139,028 | $1,772 | 204 | - | - | - | - |
$21,827 139,028 kWh |
$1,772 204 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $23,521 Cost: $1,660 |
$20,082 | 127,913 | $3,439 | 396 | - | - | - | - |
$20,082 127,913 kWh |
$3,439 396 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4321 UPGRADE OBSOLETE EQUIPMENT |
Savings: $15,163 Cost: $4,691 |
$14,225 | 90,607 | $938 | 108 | - | - | - | - |
$14,225 90,607 kWh |
$938 108 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $11,807 Cost: $22,446 |
$9,805 | 62,451 | $2,002 | 231 | - | - | - | - |
$9,805 62,451 kWh |
$2,002 231 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $7,917 Cost: $1,281 |
$7,917 | 50,425 | - | - | - | - | - | - |
$7,917 50,425 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $6,276 Cost: $1,644 |
- | - | - | - | $6,276 | 383 | - | - |
- - kWh |
- - kW-months/year |
$6,276 383 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $5,924 Cost: $40 |
$5,924 | 37,730 | - | - | - | - | - | - |
$5,924 37,730 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $5,797 Cost: $2,520 |
- | - | - | - | $5,797 | 354 | - | - |
- - kWh |
- - kW-months/year |
$5,797 354 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $5,584 Cost: $5,100 |
$4,855 | 30,924 | $729 | 84 | - | - | - | - |
$4,855 30,924 kWh |
$729 84 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
16: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS |
Savings: $849 Cost: $29 |
$789 | 5,023 | $60 | 7 | - | - | - | - |
$789 5,023 kWh |
$60 7 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $530,595 Cost: $102,665 |
$433,906 | 2,763,736 | $47,087 | 5,423 | $12,073 | 737 | $37,529 | - | $433,906 2,763,736 kWh |
$47,087 5,423 kW-months/year |
$12,073 737 MMBtu |
$37,529 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $329,104 Cost: $40,715 |
$263,805 | 1,680,287 | $21,973 | 2,531 | $5,797 | 354 | $37,529 | - | $263,805 1,680,287 kWh |
$21,973 2,531 kW-months/year |
$5,797 354 MMBtu |
$37,529 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | Administrative Changes | Electricity Usage | Electricity Demand | LPG | Administrative Changes |