IAC logo
IAC Assessment: MI0311
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MI0311
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2017
Principal Product Beer
NAICS 312120 - Breweries
SIC 2082 - Malt Beverages
Sales $10,000,000-$50,000,000
# of Employees 220
Plant Area (Sq.Ft.) 250,000
Annual Production 26,417 Thousand Gallons
Production Hrs. Annual 4,992
Location (State) PR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,700,681 12,047,520 kWh $0.14
Electricity Demand $276,811 29,215 kW-months/year $9.47
Electricity Fees $5,400 - $ -
TOTAL ENERGY COSTS $1,982,892
RECOMMENDED SAVINGS* $234,010 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $172,516
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Administrative Changes Electricity Usage Electricity Demand Administrative Changes
$ kWh $ kW-months/year $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$97,830
Cost:
$1,660
$64,505 457,480 $33,325 3,517 - - $64,505
457,480
kWh
$33,325
3,517
kW-months/year
-
-
$
02: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD Savings:
$33,524
Cost:
$10,000
$28,309 200,770 $2,615 276 $2,600 - $28,309
200,770
kWh
$2,615
276
kW-months/year
$2,600
-
$
03: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD Savings:
$28,589
Cost:
$4,520
$24,582 174,343 $4,007 419 - - $24,582
174,343
kWh
$4,007
419
kW-months/year
-
-
$
04: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$27,970
Cost:
$22,300
- - $27,970 2,952 - - -
-
kWh
$27,970
2,952
kW-months/year
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$21,644
Cost:
$21,418
$18,627 132,106 $3,017 318 - - $18,627
132,106
kWh
$3,017
318
kW-months/year
-
-
$
06: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$19,177
Cost:
$1,440
$16,441 116,603 $2,736 280 - - $16,441
116,603
kWh
$2,736
280
kW-months/year
-
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,449
Cost:
$10,720
$3,449 24,461 - - - - $3,449
24,461
kWh
-
-
kW-months/year
-
-
$
08: 2.7134 USE PHOTOCELL CONTROLS Savings:
$938
Cost:
$342
$938 6,656 - - - - $938
6,656
kWh
-
-
kW-months/year
-
-
$
09: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$889
Cost:
$1,320
$889 6,306 - - - - $889
6,306
kWh
-
-
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$234,010
Cost:
$73,720
$157,740 1,118,725 $73,670 7,762 $2,600 - $157,740
1,118,725
kWh
$73,670
7,762
kW-months/year
$2,600
-
$
TOTAL IMPLEMENTED Savings:
$172,516
Cost:
$41,420
$129,431 917,955 $43,085 4,534 - - $129,431
917,955
kWh
$43,085
4,534
kW-months/year
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Administrative Changes Electricity Usage Electricity Demand Administrative Changes