Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2017
Principal Product Zinc Coating
NAICS 332812 - Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers
SIC 3479 - Metal Coating And Allied Services
Sales $5,000,000-$10,000,000
# of Employees 28
Plant Area (Sq.Ft.) 20,000
Annual Production 11,000 Tons
Production Hrs. Annual 3,432
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $20,757 434,160 kWh $0.05
Electricity Demand $14,336 1,383 kW-months/year $10.37
Electricity Fees $5,362 - $ -
Natural Gas $154,977 50,988 MMBtu $3.04
TOTAL ENERGY COSTS $195,432
RECOMMENDED SAVINGS* $30,060 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $14,928
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$7,711
Cost:
$620
$4,228 88,088 $3,483 336 - - $4,228
88,088
kWh
$3,483
336
kW-months/year
-
-
MMBtu
02: 2.7134 USE PHOTOCELL CONTROLS Savings:
$6,519
Cost:
$720
$3,714 77,374 $2,805 271 - - $3,714
77,374
kWh
$2,805
271
kW-months/year
-
-
MMBtu
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$6,171
Cost:
$1,160
- - - - $6,171 2,030 -
-
kWh
-
-
kW-months/year
$6,171
2,030
MMBtu
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,626
Cost:
$4,300
$3,626 75,545 - - - - $3,626
75,545
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD Savings:
$2,803
Cost:
$1,580
$2,163 45,067 $640 62 - - $2,163
45,067
kWh
$640
62
kW-months/year
-
-
MMBtu
06: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE Savings:
$1,082
Cost:
$249
$616 12,824 $466 45 - - $616
12,824
kWh
$466
45
kW-months/year
-
-
MMBtu
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$992
Cost:
$3,884
$471 9,795 $521 50 - - $471
9,795
kWh
$521
50
kW-months/year
-
-
MMBtu
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$992
Cost:
$1,660
$569 11,856 $423 41 - - $569
11,856
kWh
$423
41
kW-months/year
-
-
MMBtu
09: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$164
Cost:
$574
$164 3,421 - - - - $164
3,421
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$30,060
Cost:
$14,747
$15,551 323,970 $8,338 805 $6,171 2,030 $15,551
323,970
kWh
$8,338
805
kW-months/year
$6,171
2,030
MMBtu
TOTAL IMPLEMENTED Savings:
$14,928
Cost:
$4,363
$5,063 105,475 $3,694 357 $6,171 2,030 $5,063
105,475
kWh
$3,694
357
kW-months/year
$6,171
2,030
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas