Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2017
Principal Product Electric Coils and Valves
NAICS 334416 - Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing
SIC 3677 - Electronic Coils And Transformers
Sales $1,000,000-$5,000,000
# of Employees 50
Plant Area (Sq.Ft.) 23,500
Annual Production 961,000 Pieces
Production Hrs. Annual 2,210
Location (State) PR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $79,042 456,280 kWh $0.17
Electricity Demand $23,927 2,512 kW-months/year $9.53
Electricity Fees $2,626 - $ -
TOTAL ENERGY COSTS $105,596
RECOMMENDED SAVINGS* $58,893 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $40,636
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Electricity Usage Electricity Demand Electricity Fees
$ kWh $ kW-months/year $ $
01: 2.2515 USE OPTIMUM THICKNESS INSULATION Savings:
$17,954
Cost:
$21,920
$13,821 79,891 $4,133 434 - - $13,821
79,891
kWh
$4,133
434
kW-months/year
-
-
$
02: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD Savings:
$10,816
Cost:
$7,589
$8,552 49,435 $2,264 238 - - $8,552
49,435
kWh
$2,264
238
kW-months/year
-
-
$
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$7,233
Cost:
$3,600
$7,233 41,808 - - - - $7,233
41,808
kWh
-
-
kW-months/year
-
-
$
04: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$6,777
Cost:
$5,492
$5,217 30,157 $1,560 164 - - $5,217
30,157
kWh
$1,560
164
kW-months/year
-
-
$
05: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$5,988
Cost:
$6,400
- - - - $5,988 - -
-
kWh
-
-
kW-months/year
$5,988
-
$
06: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$3,370
Cost:
$10,745
- - $3,370 354 - - -
-
kWh
$3,370
354
kW-months/year
-
-
$
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,256
Cost:
$1,660
$1,408 8,139 $848 89 - - $1,408
8,139
kWh
$848
89
kW-months/year
-
-
$
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$2,121
Cost:
$1,508
$1,972 11,400 $149 16 - - $1,972
11,400
kWh
$149
16
kW-months/year
-
-
$
09: 2.2511 INSULATE BARE EQUIPMENT Savings:
$1,612
Cost:
$1,914
$1,298 5,694 $313 33 - - $1,298
5,694
kWh
$313
33
kW-months/year
-
-
$
10: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$766
Cost:
$400
$590 3,409 $176 19 - - $590
3,409
kWh
$176
19
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$58,893
Cost:
$61,228
$40,092 229,933 $12,813 1,346 $5,988 - $40,092
229,933
kWh
$12,813
1,346
kW-months/year
$5,988
-
$
TOTAL IMPLEMENTED Savings:
$40,636
Cost:
$37,083
$32,903 188,376 $7,734 812 - - $32,903
188,376
kWh
$7,734
812
kW-months/year
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Electricity Fees Electricity Usage Electricity Demand Electricity Fees