Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,432,885 | 8,073,604 | kWh | $0.18 |
Electricity Demand | $146,636 | 15,177 | kW-months/year | $9.66 |
Electricity Fees | $2,400 | - | $ | - |
LPG | $40,877 | 1,086 | MMBtu | $37.64 |
Fuel Oil #4 | $635,460 | 56,244 | MMBtu | $11.30 |
TOTAL ENERGY COSTS | $2,258,258 | |||
RECOMMENDED SAVINGS* | $577,462 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | LPG | Fuel Oil #4 | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | LPG | Fuel Oil #4 | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $142,227 Cost: $2,030 |
$132,130 | 746,499 | $10,097 | 1,045 | - | - | - | - | - | - | - | - |
$132,130 746,499 kWh |
$10,097 1,045 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $75,087 Cost: $115,295 |
- | - | - | - | - | - | - | - | $75,087 | 6,645 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$75,087 6,645 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $69,002 Cost: $300,000 |
$51,560 | 291,301 | $3,942 | 408 | - | - | - | - | - | - | $13,500 | - |
$51,560 291,301 kWh |
$3,942 408 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
$13,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $59,009 Cost: $48,268 |
$48,046 | 271,447 | $10,963 | 1,135 | - | - | - | - | - | - | - | - |
$48,046 271,447 kWh |
$10,963 1,135 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $49,949 Cost: $6,410 |
$46,403 | 262,165 | $3,546 | 367 | - | - | - | - | - | - | - | - |
$46,403 262,165 kWh |
$3,546 367 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $49,910 Cost: $35,323 |
$45,987 | 259,815 | $3,923 | 406 | - | - | - | - | - | - | - | - |
$45,987 259,815 kWh |
$3,923 406 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $45,466 Cost: $38,639 |
$42,239 | 238,637 | $3,227 | 334 | - | - | - | - | - | - | - | - |
$42,239 238,637 kWh |
$3,227 334 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $39,872 Cost: $3,380 |
$37,041 | 209,272 | $2,831 | 293 | - | - | - | - | - | - | - | - |
$37,041 209,272 kWh |
$2,831 293 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $24,956 Cost: $7,314 |
$23,188 | 131,006 | $1,768 | 183 | - | - | - | - | - | - | - | - |
$23,188 131,006 kWh |
$1,768 183 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $17,936 Cost: $25,045 |
- | - | - | - | $17,936 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$17,936 - $ |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,246 Cost: $2,109 |
$2,525 | 14,266 | $721 | 75 | - | - | - | - | - | - | - | - |
$2,525 14,266 kWh |
$721 75 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $803 Cost: $1,560 |
- | - | - | - | - | - | $803 | 21 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$803 21 MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $577,462 Cost: $585,373 |
$429,119 | 2,424,408 | $41,017 | 4,245 | $17,936 | - | $803 | 21 | $75,087 | 6,645 | $13,500 | - | $429,119 2,424,408 kWh |
$41,017 4,245 kW-months/year |
$17,936 - $ |
$803 21 MMBtu |
$75,087 6,645 MMBtu |
$13,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||