Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2018 |
Principal Product | Processed Meat |
NAICS | 311612 - Meat Processed from Carcasses |
SIC | 2013 - Sausages And Other Prepared Meats |
Sales | $1,000,000-$5,000,000 |
# of Employees | 25 |
Plant Area (Sq.Ft.) | 29,000 |
Annual Production | 1,280,000 Pounds |
Production Hrs. Annual | 2,340 |
Location (State) | PR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $58,446 | 318,780 | kWh | $0.18 |
Electricity Demand | $11,700 | 1,033 | kW-months/year | $11.33 |
Electricity Fees | $2,529 | - | $ | - |
LPG | $14,329 | 712 | MMBtu | $20.13 |
Fuel Oil #2 | $35,949 | 1,459 | MMBtu | $24.64 |
TOTAL ENERGY COSTS | $122,953 | |||
RECOMMENDED SAVINGS* | $22,933 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $19,928 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | LPG | Electricity Usage | Electricity Demand | Electricity Fees | LPG | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $7,969 Cost: $3,100 |
$7,969 | 43,545 | - | - | - | - | - | - |
$7,969 43,545 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $6,837 Cost: $3,204 |
$5,786 | 31,617 | $1,051 | 93 | - | - | - | - |
$5,786 31,617 kWh |
$1,051 93 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,576 Cost: $3,443 |
$2,259 | 12,345 | $317 | 28 | - | - | - | - |
$2,259 12,345 kWh |
$317 28 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $1,410 Cost: $1,982 |
- | - | - | - | - | - | $1,410 | 70 |
- - kWh |
- - kW-months/year |
- - $ |
$1,410 70 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,380 Cost: $540 |
$1,153 | 6,303 | $227 | 20 | - | - | - | - |
$1,153 6,303 kWh |
$227 20 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.9112 USE SOLAR HEAT TO HEAT WATER |
Savings: $1,166 Cost: $2,755 |
$883 | 4,824 | $283 | 25 | - | - | - | - |
$883 4,824 kWh |
$283 25 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $810 Cost: $2,138 |
- | - | - | - | $810 | - | - | - |
- - kWh |
- - kW-months/year |
$810 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $785 Cost: $1,560 |
- | - | - | - | - | - | $785 | 39 |
- - kWh |
- - kW-months/year |
- - $ |
$785 39 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $22,933 Cost: $18,722 |
$18,050 | 98,634 | $1,878 | 166 | $810 | - | $2,195 | 109 | $18,050 98,634 kWh |
$1,878 166 kW-months/year |
$810 - $ |
$2,195 109 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $19,928 Cost: $13,042 |
$18,050 | 98,634 | $1,878 | 166 | - | - | - | - | $18,050 98,634 kWh |
$1,878 166 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | LPG | Electricity Usage | Electricity Demand | Electricity Fees | LPG |