Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2019 |
Principal Product | Softgels |
NAICS | 325412 - Pharmaceutical Preparation Manufacturing |
SIC | 2834 - Pharmaceutical Preparations |
Sales | $10,000,000-$50,000,000 |
# of Employees | 140 |
Plant Area (Sq.Ft.) | 70,800 |
Annual Production | 2,000,000,000 Pounds |
Production Hrs. Annual | 6,120 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $142,595 | 3,187,320 | kWh | $0.04 |
Electricity Demand | $79,797 | 6,112 | kW-months/year | $13.06 |
Electricity Fees | $49,701 | - | $ | - |
Natural Gas | $54,637 | 6,461 | MMBtu | $8.46 |
TOTAL ENERGY COSTS | $326,730 | |||
RECOMMENDED SAVINGS* | $84,271 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $68,899 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $27,411 Cost: $167,280 |
$17,475 | 388,326 | $9,936 | 761 | - | - |
$17,475 388,326 kWh |
$9,936 761 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $15,401 Cost: $2,020 |
$11,014 | 244,752 | $4,387 | 336 | - | - |
$11,014 244,752 kWh |
$4,387 336 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4321 UPGRADE OBSOLETE EQUIPMENT |
Savings: $12,811 Cost: $30,000 |
- | - | - | - | $12,811 | 1,515 |
- - kWh |
- - kW-months/year |
$12,811 1,515 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $6,851 Cost: $3,229 |
$4,370 | 97,104 | $2,481 | 190 | - | - |
$4,370 97,104 kWh |
$2,481 190 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $6,415 Cost: $18,468 |
$1,924 | 42,751 | $4,491 | 344 | - | - |
$1,924 42,751 kWh |
$4,491 344 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.9112 USE SOLAR HEAT TO HEAT WATER |
Savings: $4,487 Cost: $12,390 |
$1,553 | 34,520 | $862 | 66 | $2,072 | 245 |
$1,553 34,520 kWh |
$862 66 kW-months/year |
$2,072 245 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1221 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES |
Savings: $4,470 Cost: $10,760 |
$4,315 | 95,890 | $2,455 | 188 | $(-2,300) | (-272) |
$4,315 95,890 kWh |
$2,455 188 kW-months/year |
$(-2,300) (-272) MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,201 Cost: $750 |
$2,039 | 45,312 | $1,162 | 89 | - | - |
$2,039 45,312 kWh |
$1,162 89 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,936 Cost: $7,601 |
$2,127 | 47,266 | $809 | 62 | - | - |
$2,127 47,266 kWh |
$809 62 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $288 Cost: $507 |
$144 | 3,211 | $144 | 11 | - | - |
$144 3,211 kWh |
$144 11 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $84,271 Cost: $253,005 |
$44,961 | 999,132 | $26,727 | 2,047 | $12,583 | 1,488 | $44,961 999,132 kWh |
$26,727 2,047 kW-months/year |
$12,583 1,488 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $68,899 Cost: $211,387 |
$37,169 | 825,971 | $18,919 | 1,449 | $12,811 | 1,515 | $37,169 825,971 kWh |
$18,919 1,449 kW-months/year |
$12,811 1,515 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |