IAC logo
IAC Assessment: MI0375
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MI0375
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2020
Principal Product refrigeration products
NAICS 336390 - Other Motor Vehicle Parts Manufacturing
SIC 3585 - Refrigeration And Heating Equipment
Sales $10,000,000-$50,000,000
# of Employees 100
Plant Area (Sq.Ft.) 82,725
Annual Production 50,000 Pieces
Production Hrs. Annual 2,340
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $74,585 1,512,787 kWh $0.05
Electricity Demand $63,873 5,716 kW-months/year $11.17
Electricity Fees $25,580 - $ -
TOTAL ENERGY COSTS $164,038
RECOMMENDED SAVINGS* $22,091 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $17,261
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD Savings:
$9,722
Cost:
$20,153
$2,861 58,387 $6,861 614 $2,861
58,387
kWh
$6,861
614
kW-months/year
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,712
Cost:
$2,100
$2,360 48,162 $1,352 121 $2,360
48,162
kWh
$1,352
121
kW-months/year
03: 2.7228 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM Savings:
$1,971
Cost:
$965
$1,256 25,629 $715 64 $1,256
25,629
kWh
$715
64
kW-months/year
04: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$1,948
Cost:
$2,692
$898 18,330 $1,050 94 $898
18,330
kWh
$1,050
94
kW-months/year
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,932
Cost:
$4,843
$893 18,232 $1,039 93 $893
18,232
kWh
$1,039
93
kW-months/year
06: 2.2523 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS Savings:
$939
Cost:
$280
$436 8,888 $503 45 $436
8,888
kWh
$503
45
kW-months/year
07: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$911
Cost:
$1,214
$419 8,553 $492 44 $419
8,553
kWh
$492
44
kW-months/year
08: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$617
Cost:
$1,522
$617 12,587 - - $617
12,587
kWh
-
-
kW-months/year
09: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$339
Cost:
$984
$127 2,593 $212 19 $127
2,593
kWh
$212
19
kW-months/year
TOTAL RECOMMENDED Savings:
$22,091
Cost:
$34,753
$9,867 201,361 $12,224 1,094 $9,867
201,361
kWh
$12,224
1,094
kW-months/year
TOTAL IMPLEMENTED Savings:
$17,261
Cost:
$29,882
$7,294 148,849 $9,967 892 $7,294
148,849
kWh
$9,967
892
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand