IAC Center | University of Miami |
---|---|
Assessment Year | 2020 |
Principal Product | electronic parts for AIrcrafts |
NAICS | 336413 - Other Aircraft Parts and Auxiliary Equipment Manufacturing |
SIC | 3728 - Aircraft Parts And Equipment, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 210 |
Plant Area (Sq.Ft.) | 128,000 |
Annual Production | 941,402 Pieces |
Production Hrs. Annual | 2,100 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $178,956 | 4,617,408 | kWh | $0.04 |
Electricity Demand | $141,749 | 10,465 | kW-months/year | $13.55 |
Electricity Fees | $23,464 | - | $ | - |
TOTAL ENERGY COSTS | $344,169 | |||
RECOMMENDED SAVINGS* | $112,914 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $86,204 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $69,936 Cost: $480 |
$47,478 | 1,217,374 | $22,458 | 1,658 | - | - |
$47,478 1,217,374 kWh |
$22,458 1,658 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.9112 USE SOLAR HEAT TO HEAT WATER |
Savings: $26,710 Cost: $12,200 |
$23,134 | 593,190 | $3,576 | 264 | - | - |
$23,134 593,190 kWh |
$3,576 264 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $4,404 Cost: $16,320 |
$2,941 | 75,411 | $1,463 | 108 | - | - |
$2,941 75,411 kWh |
$1,463 108 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $3,546 Cost: $3,927 |
$2,408 | 61,747 | $1,138 | 84 | - | - |
$2,408 61,747 kWh |
$1,138 84 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,610 Cost: $2,100 |
$1,745 | 44,738 | $865 | 64 | - | - |
$1,745 44,738 kWh |
$865 64 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,477 Cost: $8,668 |
$830 | 21,273 | $1,647 | 122 | - | - |
$830 21,273 kWh |
$1,647 122 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.8123 PAY UTILITY BILLS ON TIME |
Savings: $1,659 Cost: - |
- | - | - | - | $1,659 | - |
- - kWh |
- - kW-months/year |
$1,659 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,572 Cost: $1,980 |
$1,085 | 27,818 | $487 | 36 | - | - |
$1,085 27,818 kWh |
$487 36 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $112,914 Cost: $45,675 |
$79,621 | 2,041,551 | $31,634 | 2,335 | $1,659 | - | $79,621 2,041,551 kWh |
$31,634 2,335 kW-months/year |
$1,659 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $86,204 Cost: $33,475 |
$56,487 | 1,448,361 | $28,058 | 2,071 | $1,659 | - | $56,487 1,448,361 kWh |
$28,058 2,071 kW-months/year |
$1,659 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees |