Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2021 |
Principal Product | Chemical Bleach |
NAICS | 325180 - Other Basic Inorganic Chemical Manufacturing |
SIC | 2819 - Industrial Inorganic Chemicals, Nec |
Sales | $100,000,000-$500,000,000 |
# of Employees | 31 |
Plant Area (Sq.Ft.) | 44,000 |
Annual Production | 30,000 Thousand Gallons |
Production Hrs. Annual | 8,568 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,911,286 | 41,280,592 | kWh | $0.05 |
Electricity Demand | $92,608 | 67,786 | kW-months/year | $1.37 |
Electricity Fees | $243,187 | - | $ | - |
Natural Gas | $30,600 | 9,153 | MMBtu | $3.34 |
TOTAL ENERGY COSTS | $2,277,681 | |||
RECOMMENDED SAVINGS* | $135,694 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $6,433 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $100,476 Cost: $227,400 |
- | - | - | - | $100,476 | - | - | - |
- - kWh |
- - kW-months/year |
$100,476 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $685 Cost: $480 |
$660 | 13,210 | $25 | 18 | - | - | - | - |
$660 13,210 kWh |
$25 18 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $4,195 Cost: $1,126 |
$4,043 | 80,872 | $152 | 111 | - | - | - | - |
$4,043 80,872 kWh |
$152 111 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $11,648 Cost: $3,107 |
$11,226 | 224,511 | $422 | 308 | - | - | - | - |
$11,226 224,511 kWh |
$422 308 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.9112 USE SOLAR HEAT TO HEAT WATER |
Savings: $12,942 Cost: $72,248 |
- | - | - | - | - | - | $12,942 | 3,875 |
- - kWh |
- - kW-months/year |
- - $ |
$12,942 3,875 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,748 Cost: $2,211 |
$5,092 | 101,833 | $656 | 479 | - | - | - | - |
$5,092 101,833 kWh |
$656 479 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $135,694 Cost: $306,572 |
$21,021 | 420,426 | $1,255 | 916 | $100,476 | - | $12,942 | 3,875 | $21,021 420,426 kWh |
$1,255 916 kW-months/year |
$100,476 - $ |
$12,942 3,875 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $6,433 Cost: $2,691 |
$5,752 | 115,043 | $681 | 497 | - | - | - | - | $5,752 115,043 kWh |
$681 497 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |