Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2022
Principal Product Electroplating
NAICS 332813 - Electroplating, Plating, Polishing, Anodizing, and Coloring
SIC 3471 - Plating And Polishing
Sales $5,000,000-$10,000,000
# of Employees 84
Plant Area (Sq.Ft.) 133,000
Annual Production 5,000,000 Pieces
Production Hrs. Annual 4,160
Location (State) PR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $307,603 1,532,503 kWh $0.20
Electricity Demand $67,285 6,170 kW-months/year $10.91
Electricity Fees $3,479 - $ -
Fuel Oil #2 $282,499 14,837 MMBtu $19.04
TOTAL ENERGY COSTS $660,866
RECOMMENDED SAVINGS* $49,444 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $47,788
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Fuel Oil #2 Electricity Usage Electricity Demand Electricity Fees Fuel Oil #2
$ kWh $ kW-months/year $ $ $ MMBtu
01: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$15,827
Cost:
$43,707
- - - - $15,827 - - - -
-
kWh
-
-
kW-months/year
$15,827
-
$
-
-
MMBtu
02: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$11,648
Cost:
$5,536
$10,072 50,107 $1,576 145 - - - - $10,072
50,107
kWh
$1,576
145
kW-months/year
-
-
$
-
-
MMBtu
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$9,718
Cost:
$2,020
$8,737 43,470 $981 90 - - - - $8,737
43,470
kWh
$981
90
kW-months/year
-
-
$
-
-
MMBtu
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,275
Cost:
$5,780
$4,541 22,593 $734 67 - - - - $4,541
22,593
kWh
$734
67
kW-months/year
-
-
$
-
-
MMBtu
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$4,149
Cost:
$40
$3,573 17,777 $576 53 - - - - $3,573
17,777
kWh
$576
53
kW-months/year
-
-
$
-
-
MMBtu
06: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$1,656
Cost:
$480
- - - - - - $1,656 87 -
-
kWh
-
-
kW-months/year
-
-
$
$1,656
87
MMBtu
07: 2.6127 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT Savings:
$1,171
Cost:
$99
$1,007 5,011 $164 15 - - - - $1,007
5,011
kWh
$164
15
kW-months/year
-
-
$
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$49,444
Cost:
$57,662
$27,930 138,958 $4,031 370 $15,827 - $1,656 87 $27,930
138,958
kWh
$4,031
370
kW-months/year
$15,827
-
$
$1,656
87
MMBtu
TOTAL IMPLEMENTED Savings:
$47,788
Cost:
$57,182
$27,930 138,958 $4,031 370 $15,827 - - - $27,930
138,958
kWh
$4,031
370
kW-months/year
$15,827
-
$
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ $ $ MMBtu
Electricity Usage Electricity Demand Electricity Fees Fuel Oil #2 Electricity Usage Electricity Demand Electricity Fees Fuel Oil #2