Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2023
Principal Product Vitamins, Supplements
NAICS 325412 - Pharmaceutical Preparation Manufacturing
SIC 2834 - Pharmaceutical Preparations
Sales $50,000,000-$100,000,000
# of Employees 340
Plant Area (Sq.Ft.) 132,000
Annual Production 12,480,000 Pieces
Production Hrs. Annual 4,160
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $103,792 1,720,688 kWh $0.06
Electricity Demand $69,988 4,663 kW-months/year $15.01
Electricity Fees $47,499 - $ -
TOTAL ENERGY COSTS $221,279
RECOMMENDED SAVINGS* $3,202,254 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $3,202,254
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Primary Product Electricity Usage Electricity Demand Primary Product
$ kWh $ kW-months/year $ $
01: 2.7273 INSTALL DESICCANT HUMIDITY CONTROL SYSTEM Savings:
$3,141,406
Cost:
$1,000,000
$(-4,992) (-83,200) $(-3,602) (-240) $3,150,000 - $(-4,992)
(-83,200)
kWh
$(-3,602)
(-240)
kW-months/year
$3,150,000
-
$
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$22,029
Cost:
$480
$12,798 213,308 $9,231 615 - - $12,798
213,308
kWh
$9,231
615
kW-months/year
-
-
$
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$14,894
Cost:
$1,980
$8,650 144,163 $6,244 416 - - $8,650
144,163
kWh
$6,244
416
kW-months/year
-
-
$
04: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$5,903
Cost:
$1,827
- - $5,903 393 - - -
-
kWh
$5,903
393
kW-months/year
-
-
$
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$4,785
Cost:
$13,440
$2,804 46,737 $1,981 132 - - $2,804
46,737
kWh
$1,981
132
kW-months/year
-
-
$
06: 2.7229 AIR CONDITION ONLY SPACE NECESSARY Savings:
$3,663
Cost:
$3,360
$3,663 61,047 - - - - $3,663
61,047
kWh
-
-
kW-months/year
-
-
$
07: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE Savings:
$2,508
Cost:
-
$1,457 24,279 $1,051 70 - - $1,457
24,279
kWh
$1,051
70
kW-months/year
-
-
$
08: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$1,021
Cost:
$199
$760 12,660 $261 17 - - $760
12,660
kWh
$261
17
kW-months/year
-
-
$
09: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$6,045
Cost:
-
- - $6,045 403 - - -
-
kWh
$6,045
403
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$3,202,254
Cost:
$1,021,286
$25,140 418,994 $27,114 1,807 $3,150,000 - $25,140
418,994
kWh
$27,114
1,807
kW-months/year
$3,150,000
-
$
TOTAL IMPLEMENTED Savings:
$3,202,254
Cost:
$1,021,286
$25,140 418,994 $27,114 1,807 $3,150,000 - $25,140
418,994
kWh
$27,114
1,807
kW-months/year
$3,150,000
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Primary Product Electricity Usage Electricity Demand Primary Product