Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2024 |
Principal Product | 1. Piezes, solenoids, switches, 2. Thermoplastics ( contactors and starters) |
NAICS | 335313 - Switchgear and Switchboard Apparatus Manufacturing |
SIC | 3613 - Switchgear And Switchboard Apparatus |
Sales | $10,000,000-$50,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 236,000 |
Annual Production | 50,000,000 Units |
Production Hrs. Annual | 6,656 |
Location (State) | PR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $832,093 | 3,907,609 | kWh | $0.21 |
Electricity Demand | $89,566 | 11,166 | kW-months/year | $8.02 |
Electricity Fees | $5,881 | - | $ | - |
TOTAL ENERGY COSTS | $927,540 | |||
RECOMMENDED SAVINGS* | $86,098 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Usage | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Water Usage | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.3125 USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS |
Savings: $43,981 Cost: $80,000 |
- | - | - | - | $6,444 | 54 | $37,537 | - |
- - kWh |
- - kW-months/year |
$6,444 54 Tgal |
$37,537 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $14,805 Cost: $1,620 |
$12,841 | 60,285 | $1,964 | 245 | - | - | - | - |
$12,841 60,285 kWh |
$1,964 245 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $14,219 Cost: $14,799 |
$13,313 | 62,504 | $906 | 113 | - | - | - | - |
$13,313 62,504 kWh |
$906 113 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $8,976 Cost: $11,882 |
$8,405 | 39,458 | $571 | 71 | - | - | - | - |
$8,405 39,458 kWh |
$571 71 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $4,117 Cost: $1,690 |
$4,117 | 19,329 | - | - | - | - | - | - |
$4,117 19,329 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $86,098 Cost: $109,991 |
$38,676 | 181,576 | $3,441 | 429 | $6,444 | 54 | $37,537 | - | $38,676 181,576 kWh |
$3,441 429 kW-months/year |
$6,444 54 Tgal |
$37,537 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Usage | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Water Usage | One-time Revenue or Avoided Cost |