Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Missouri, Rolla |
---|---|
Assessment Year | 1997 |
Principal Product | Pillows and Cushions |
NAICS | n/a |
SIC | 2392 - Housefurnishings, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 44,000 |
Annual Production | 1,800,000 Pieces |
Production Hrs. Annual | 3,380 |
Location (State) | MO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $21,542 | 652,989 | kWh | $0.03 |
Electricity Demand | $18,062 | 300 | kW-months/year | $60.21 |
Electricity Fees | $2,467 | - | $ | - |
Natural Gas | $17,269 | 2,051 | MMBtu | $8.42 |
TOTAL ENERGY COSTS | $72,294 | |||
RECOMMENDED SAVINGS* | $30,332 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $11,435 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.432 CROSS-TRAIN PERSONNEL TO AVOID LOST TIME |
Savings: $4,640 Cost: $12,500 |
- | - | - | - | - | - | $4,640 | - |
- - kWh |
- - kW-months/year |
- - lb |
$4,640 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $3,960 Cost: $10,000 |
- | - | - | - | - | - | $3,960 | - |
- - kWh |
- - kW-months/year |
- - lb |
$3,960 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,211 Cost: $4,172 |
$1,392 | 37,808 | $819 | 14 | - | - | - | - |
$1,392 37,808 kWh |
$819 14 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,394 Cost: $3,145 |
$870 | 23,740 | $524 | 9 | - | - | - | - |
$870 23,740 kWh |
$524 9 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $86 Cost: $207 |
$74 | 2,052 | $12 | 1 | - | - | - | - |
$74 2,052 kWh |
$12 1 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,441 Cost: $52 |
$827 | 22,567 | $614 | 10 | - | - | - | - |
$827 22,567 kWh |
$614 10 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.7196 USE RE-USABLE FILTERS |
Savings: $12,954 Cost: $4,229 |
- | - | - | - | $12,954 | 3,200 | - | - |
- - kWh |
- - kW-months/year |
$12,954 3,200 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $3,646 Cost: $5,240 |
- | - | - | - | $3,646 | 1,275 | - | - |
- - kWh |
- - kW-months/year |
$3,646 1,275 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $30,332 Cost: $39,545 |
$3,163 | 86,167 | $1,969 | 34 | $16,600 | 4,475 | $8,600 | - | $3,163 86,167 kWh |
$1,969 34 kW-months/year |
$16,600 4,475 lb |
$8,600 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $11,435 Cost: $25,697 |
$1,697 | 46,307 | $1,138 | 19 | - | - | $8,600 | - | $1,697 46,307 kWh |
$1,138 19 kW-months/year |
- - lb |
$8,600 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Ancillary Material Cost |