Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Missouri, Rolla |
---|---|
Assessment Year | 1997 |
Principal Product | Color Separations |
NAICS | n/a |
SIC | 2752 - Commercial Printing, Lithographic |
Sales | $10,000,000-$50,000,000 |
# of Employees | 365 |
Plant Area (Sq.Ft.) | 104,654 |
Annual Production | 254,069 Units |
Production Hrs. Annual | 8,736 |
Location (State) | MO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $135,739 | 2,721,571 | kWh | $0.05 |
Electricity Demand | $12,047 | 603 | kW-months/year | $19.98 |
Electricity Fees | $15,284 | - | $ | - |
Natural Gas | $6,891 | 1,205 | MMBtu | $5.72 |
TOTAL ENERGY COSTS | $174,401 | |||
RECOMMENDED SAVINGS* | $40,945 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $21,859 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.432 CROSS-TRAIN PERSONNEL TO AVOID LOST TIME |
Savings: $12,968 Cost: $25,000 |
- | - | - | - | - | - | $12,968 | - |
- - kWh |
- - kW-months/year |
- - lb |
$12,968 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $5,861 Cost: $12,500 |
- | - | - | - | - | - | $5,861 | - |
- - kWh |
- - kW-months/year |
- - lb |
$5,861 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $11,219 Cost: $9,884 |
$10,691 | 192,849 | $528 | 26 | - | - | - | - |
$10,691 192,849 kWh |
$528 26 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,779 Cost: $1,126 |
$4,553 | 82,063 | $226 | 11 | - | - | - | - |
$4,553 82,063 kWh |
$226 11 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $617 Cost: $1,104 |
$593 | 10,844 | $24 | 1 | - | - | - | - |
$593 10,844 kWh |
$24 1 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $4,440 Cost: $5,240 |
- | - | - | - | $4,440 | 7,072 | - | - |
- - kWh |
- - kW-months/year |
$4,440 7,072 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.7196 USE RE-USABLE FILTERS |
Savings: $1,061 Cost: $1,515 |
- | - | - | - | $1,061 | 360 | - | - |
- - kWh |
- - kW-months/year |
$1,061 360 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $40,945 Cost: $56,369 |
$15,837 | 285,756 | $778 | 38 | $5,501 | 7,432 | $18,829 | - | $15,837 285,756 kWh |
$778 38 kW-months/year |
$5,501 7,432 lb |
$18,829 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $21,859 Cost: $23,510 |
$15,244 | 274,912 | $754 | 37 | - | - | $5,861 | - | $15,244 274,912 kWh |
$754 37 kW-months/year |
- - lb |
$5,861 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Ancillary Material Cost |