Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Missouri, Rolla |
---|---|
Assessment Year | 1999 |
Principal Product | Plastic Injection Molded Hospital Supplies |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 390 |
Plant Area (Sq.Ft.) | 165,800 |
Annual Production | 392,000 Units |
Production Hrs. Annual | 6,120 |
Location (State) | MO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $307,950 | 7,158,851 | kWh | $0.04 |
Electricity Demand | $24,858 | 1,431 | kW-months/year | $17.37 |
Electricity Fees | $40,897 | - | $ | - |
Natural Gas | $55,012 | 18,386 | MMBtu | $2.99 |
TOTAL ENERGY COSTS | $641,632 | |||
RECOMMENDED SAVINGS* | $267,651 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $315 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $8,133 Cost: $14,908 |
$7,640 | 156,800 | $493 | 28 | - | - | - | - |
$7,640 156,800 kWh |
$493 28 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $721 Cost: $40 |
$681 | 14,068 | $40 | 2 | - | - | - | - |
$681 14,068 kWh |
$40 2 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS |
Savings: $192,000 Cost: - |
- | - | - | - | $192,000 | 40,000 | - | - |
- - kWh |
- - kW-months/year |
$192,000 40,000 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $315 Cost: - |
- | - | - | - | $315 | 7 | - | - |
- - kWh |
- - kW-months/year |
$315 7 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.425 ELIMINATE/REDUCE REDUNDANT INSPECTIONS |
Savings: $66,482 Cost: $156,000 |
- | - | - | - | - | - | $66,482 | - |
- - kWh |
- - kW-months/year |
- - lb |
$66,482 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $267,651 Cost: $170,948 |
$8,321 | 170,868 | $533 | 30 | $192,315 | 40,007 | $66,482 | - | $8,321 170,868 kWh |
$533 30 kW-months/year |
$192,315 40,007 lb |
$66,482 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $315 Cost: - |
- | - | - | - | $315 | 7 | - | - | - - kWh |
- - kW-months/year |
$315 7 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes |