Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Mississippi State
Assessment Year 1995
Principal Product Boilers and Water Treatment Systems
NAICS n/a
SIC 3443 - Fabricated Plate Work (boiler Shops)
Sales $10,000,000-$50,000,000
# of Employees 200
Plant Area (Sq.Ft.) 52,000
Annual Production 1,000 Pieces
Production Hrs. Annual 4,000
Location (State) MS
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $124,778 1,735,053 kWh $0.07
Natural Gas $29,969 7,530 MMBtu $3.98
TOTAL ENERGY COSTS $154,747
RECOMMENDED SAVINGS* $15,725 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $6,555
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$686
Cost:
$2,455
$686 12,896 - - $686
12,896
kWh
-
-
MMBtu
02: 2.7122 DISCONNECT BALLASTS Savings:
$1,005
Cost:
$200
$1,005 19,637 - - $1,005
19,637
kWh
-
-
MMBtu
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$407
Cost:
$321
$407 7,620 - - $407
7,620
kWh
-
-
MMBtu
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$3,696
Cost:
$3,080
- - $3,696 915 -
-
kWh
$3,696
915
MMBtu
05: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$818
Cost:
$730
$818 18,757 - - $818
18,757
kWh
-
-
MMBtu
06: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$8,484
Cost:
$21,600
- - $8,484 2,100 -
-
kWh
$8,484
2,100
MMBtu
07: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$629
Cost:
-
$629 14,361 - - $629
14,361
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$15,725
Cost:
$28,386
$3,545 73,271 $12,180 3,015 $3,545
73,271
kWh
$12,180
3,015
MMBtu
TOTAL IMPLEMENTED Savings:
$6,555
Cost:
$4,331
$2,859 60,375 $3,696 915 $2,859
60,375
kWh
$3,696
915
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas