Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Mississippi State
Assessment Year 1995
Principal Product Furniture
NAICS n/a
SIC 2521 - Wood Office Furniture
Sales $10,000,000-$50,000,000
# of Employees 400
Plant Area (Sq.Ft.) 260,000
Annual Production 212,500 Pieces
Production Hrs. Annual 2,000
Location (State) MS
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $149,005 2,452,521 kWh $0.06
Natural Gas $34,237 5,219 MMBtu $6.56
TOTAL ENERGY COSTS $183,242
RECOMMENDED SAVINGS* $41,760 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $5,981
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$817
Cost:
$50
$817 23,740 - - $817
23,740
kWh
-
-
MMBtu
02: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$5,164
Cost:
$2,130
$5,164 - - - $5,164
-
kWh
-
-
MMBtu
03: 2.2428 USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC Savings:
$11,921
Cost:
$12,146
- - $11,921 1,820 -
-
kWh
$11,921
1,820
MMBtu
04: 2.6214 SHUT OFF PILOTS IN STANDBY EQUIPMENT Savings:
$678
Cost:
$20
- - $678 103 -
-
kWh
$678
103
MMBtu
05: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$2,158
Cost:
$5,000
$2,158 70,926 - - $2,158
70,926
kWh
-
-
MMBtu
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,824
Cost:
$4,949
$2,824 41,618 - - $2,824
41,618
kWh
-
-
MMBtu
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$18,198
Cost:
$32,850
- - $18,198 2,777 -
-
kWh
$18,198
2,777
MMBtu
TOTAL RECOMMENDED Savings:
$41,760
Cost:
$57,145
$10,963 136,284 $30,797 4,700 $10,963
136,284
kWh
$30,797
4,700
MMBtu
TOTAL IMPLEMENTED Savings:
$5,981
Cost:
$2,180
$5,981 23,740 - - $5,981
23,740
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas