Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Mississippi State
Assessment Year 1995
Principal Product Heating Coils
NAICS n/a
SIC 3699 - Electrical Equipment & Supplies, Nec
Sales $50,000,000-$100,000,000
# of Employees 464
Plant Area (Sq.Ft.) 186,000
Annual Production 14,000,000 Pieces
Production Hrs. Annual 6,120
Location (State) AL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $554,144 12,827,374 kWh $0.04
Natural Gas $34,893 6,187 MMBtu $5.64
TOTAL ENERGY COSTS $589,037
RECOMMENDED SAVINGS* $40,474 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $2,628
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$2,481
Cost:
$1,400
$2,481 97,597 $2,481
97,597
kWh
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,552
Cost:
$5,300
$1,552 44,549 $1,552
44,549
kWh
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$30,745
Cost:
$1,300
$30,745 873,974 $30,745
873,974
kWh
04: 2.2514 COVER OPEN TANKS Savings:
$276
Cost:
$420
$276 10,844 $276
10,844
kWh
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$5,273
Cost:
$10,121
$5,273 97,304 $5,273
97,304
kWh
06: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$147
Cost:
$140
$147 5,862 $147
5,862
kWh
TOTAL RECOMMENDED Savings:
$40,474
Cost:
$18,681
$40,474 1,130,130 $40,474
1,130,130
kWh
TOTAL IMPLEMENTED Savings:
$2,628
Cost:
$1,540
$2,628 103,459 $2,628
103,459
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage