Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 1996 |
Principal Product | Defense Electronic Subsystems |
NAICS | n/a |
SIC | 3812 - Search And Navigation Equipment |
Sales | $100,000,000-$500,000,000 |
# of Employees | 320 |
Plant Area (Sq.Ft.) | 352,000 |
Annual Production | 670 Pieces |
Production Hrs. Annual | 2,496 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $596,150 | 15,240,035 | kWh | $0.04 |
Electricity Demand | $128,495 | 32,573 | kW-months/year | $3.94 |
Electricity Fees | $(-36,239) | - | $ | - |
Natural Gas | $54,079 | 13,373 | MMBtu | $4.04 |
TOTAL ENERGY COSTS | $742,485 | |||
RECOMMENDED SAVINGS* | $48,736 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $22,670 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $517 Cost: $2,000 |
- | - | - | - | $517 | 129 | - | - |
- - kWh |
- - kW-months/year |
$517 129 MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $7,370 Cost: $1,882 |
$5,227 | 155,627 | $4,284 | 504 | $(-2,141) | (-531) | - | - |
$5,227 155,627 kWh |
$4,284 504 kW-months/year |
$(-2,141) (-531) MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $14,049 Cost: $1,940 |
$8,607 | 256,155 | $5,442 | 1,280 | - | - | - | - |
$8,607 256,155 kWh |
$5,442 1,280 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $15,300 Cost: - |
- | - | $15,300 | 3,600 | - | - | - | - |
- - kWh |
$15,300 3,600 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $11,500 Cost: $6,500 |
- | - | - | - | - | - | $11,500 | 200,000 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$11,500 200,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $48,736 Cost: $12,322 |
$13,834 | 411,782 | $25,026 | 5,384 | $(-1,624) | (-402) | $11,500 | 200,000 | $13,834 411,782 kWh |
$25,026 5,384 kW-months/year |
$(-1,624) (-402) MMBtu |
$11,500 200,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $22,670 Cost: $1,882 |
$5,227 | 155,627 | $19,584 | 4,104 | $(-2,141) | (-531) | - | - | $5,227 155,627 kWh |
$19,584 4,104 kW-months/year |
$(-2,141) (-531) MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) |