Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Mississippi State
Assessment Year 1996
Principal Product control valves
NAICS n/a
SIC 3491 - Industrial Valves
Sales $10,000,000-$50,000,000
# of Employees 160
Plant Area (Sq.Ft.) 70,000
Annual Production 400,000 Pieces
Production Hrs. Annual 4,000
Location (State) MS
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $102,005 2,068,875 kWh $0.05
Electricity Demand $16,100 5,651 kW-months/year $2.85
Electricity Fees $28,693 - $ -
Natural Gas $7,214 1,521 MMBtu $4.74
TOTAL ENERGY COSTS $157,797
RECOMMENDED SAVINGS* $21,008 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $1,762
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Natural Gas Other Liquid (non-haz) Other Liquid (haz) Administrative Changes Electricity Usage Electricity Demand Electricity Fees Natural Gas Other Liquid (non-haz) Other Liquid (haz) Administrative Changes
$ kWh $ kW-months/year $ $ $ MMBtu $ gal $ gal $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,762
Cost:
$4,217
$1,214 27,550 $251 100 $297 - - - - - - - - - $1,214
27,550
kWh
$251
100
kW-months/year
$297
-
$
-
-
MMBtu
-
-
gal
-
-
gal
-
-
$
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$10,574
Cost:
$39,728
$9,658 220,106 $2,648 1,056 $2,678 - $(-4,410) (-938) - - - - - - $9,658
220,106
kWh
$2,648
1,056
kW-months/year
$2,678
-
$
$(-4,410)
(-938)
MMBtu
-
-
gal
-
-
gal
-
-
$
03: 2.7227 USE WATER ON AIR CONDITIONING EXCHANGER TO IMPROVE HEAT TRANSFER AND INCREASE AIR CONDITIONER EFFICIENCY Savings:
$1,724
Cost:
$7,665
$1,826 41,618 $48 19 $189 - - - $(-339) (-226,015) - - - - $1,826
41,618
kWh
$48
19
kW-months/year
$189
-
$
-
-
MMBtu
$(-339)
(-226,015)
gal
-
-
gal
-
-
$
04: 3.7196 USE RE-USABLE FILTERS Savings:
$900
Cost:
$1,500
- - - - - - - - - - - - $900 - -
-
kWh
-
-
kW-months/year
-
-
$
-
-
MMBtu
-
-
gal
-
-
gal
$900
-
$
05: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS Savings:
$6,048
Cost:
$20,000
- - - - - - $(-287) (-60) - - $6,335 3,683 - - -
-
kWh
-
-
kW-months/year
-
-
$
$(-287)
(-60)
MMBtu
-
-
gal
$6,335
3,683
gal
-
-
$
TOTAL RECOMMENDED Savings:
$21,008
Cost:
$73,110
$12,698 289,274 $2,947 1,175 $3,164 - $(-4,697) (-998) $(-339) (-226,015) $6,335 3,683 $900 - $12,698
289,274
kWh
$2,947
1,175
kW-months/year
$3,164
-
$
$(-4,697)
(-998)
MMBtu
$(-339)
(-226,015)
gal
$6,335
3,683
gal
$900
-
$
TOTAL IMPLEMENTED Savings:
$1,762
Cost:
$4,217
$1,214 27,550 $251 100 $297 - - - - - - - - - $1,214
27,550
kWh
$251
100
kW-months/year
$297
-
$
-
-
MMBtu
-
-
gal
-
-
gal
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ MMBtu $ gal $ gal $ $
Electricity Usage Electricity Demand Electricity Fees Natural Gas Other Liquid (non-haz) Other Liquid (haz) Administrative Changes Electricity Usage Electricity Demand Electricity Fees Natural Gas Other Liquid (non-haz) Other Liquid (haz) Administrative Changes