Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 1996 |
Principal Product | pants |
NAICS | n/a |
SIC | 2325 - Men's and Boys' Separate Trousers and Slacks |
Sales | $50,000,000-$100,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 219,000 |
Annual Production | 6,875,000 Pieces |
Production Hrs. Annual | 4,165 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $137,701 | 3,761,430 | kWh | $0.04 |
Electricity Demand | $83,315 | 13,343 | kW-months/year | $6.24 |
Electricity Fees | $4,496 | - | $ | - |
Natural Gas | $45,183 | 10,006 | MMBtu | $4.52 |
TOTAL ENERGY COSTS | $265,605 | |||
RECOMMENDED SAVINGS* | $18,651 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $4,192 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,116 Cost: $10,500 |
$1,291 | 41,618 | $1,825 | 225 | - | - | - | - | - | - | - | - |
$1,291 41,618 kWh |
$1,825 225 kW-months/year |
- - $ |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7227 USE WATER ON AIR CONDITIONING EXCHANGER TO IMPROVE HEAT TRANSFER AND INCREASE AIR CONDITIONER EFFICIENCY |
Savings: $1,213 Cost: $5,100 |
$1,360 | 43,962 | $211 | 26 | - | - | $(-358) | (-238,570) | - | - | - | - |
$1,360 43,962 kWh |
$211 26 kW-months/year |
- - $ |
$(-358) (-238,570) Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4312 IMPROVE LUBRICATION PRACTICES |
Savings: $1,076 Cost: $150 |
$588 | 18,757 | $488 | 60 | - | - | - | - | - | - | - | - |
$588 18,757 kWh |
$488 60 kW-months/year |
- - $ |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7228 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM |
Savings: $2,888 Cost: $3,000 |
$2,888 | 93,200 | - | - | - | - | - | - | - | - | - | - |
$2,888 93,200 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $2,424 Cost: $7,000 |
$2,424 | 78,253 | - | - | - | - | - | - | - | - | - | - |
$2,424 78,253 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $3,866 Cost: - |
- | - | - | - | $3,866 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,866 - $ |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.7196 USE RE-USABLE FILTERS |
Savings: $648 Cost: $1,080 |
- | - | - | - | - | - | - | - | - | - | $648 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - lb |
$648 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $3,420 Cost: - |
- | - | - | - | - | - | - | - | $3,420 | 228,000 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
$3,420 228,000 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $18,651 Cost: $26,830 |
$8,551 | 275,790 | $2,524 | 311 | $3,866 | - | $(-358) | (-238,570) | $3,420 | 228,000 | $648 | - | $8,551 275,790 kWh |
$2,524 311 kW-months/year |
$3,866 - $ |
$(-358) (-238,570) Tgal |
$3,420 228,000 lb |
$648 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $4,192 Cost: $10,650 |
$1,879 | 60,375 | $2,313 | 285 | - | - | - | - | - | - | - | - | $1,879 60,375 kWh |
$2,313 285 kW-months/year |
- - $ |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Solid Waste (non-haz) | Administrative Changes |