Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 1996 |
Principal Product | Metal Hardware |
NAICS | n/a |
SIC | 3429 - Hardware, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 264 |
Plant Area (Sq.Ft.) | 281,500 |
Annual Production | 10,240,000 Pounds |
Production Hrs. Annual | 4,000 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $150,430 | 3,539,566 | kWh | $0.04 |
Electricity Demand | $62,785 | 10,502 | kW-months/year | $5.98 |
Electricity Fees | $14,335 | - | $ | - |
Natural Gas | $140,470 | 35,189 | MMBtu | $3.99 |
TOTAL ENERGY COSTS | $368,767 | |||
RECOMMENDED SAVINGS* | $38,486 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $25,251 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $7,748 Cost: $1,675 |
$7,748 | 182,298 | - | - | - | - | - | - | - | - |
$7,748 182,298 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $12,252 Cost: $7,353 |
- | - | - | - | $12,252 | 3,003 | - | - | - | - |
- - kWh |
- - kW-months/year |
$12,252 3,003 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $12,999 Cost: $35,867 |
$8,337 | 198,417 | $4,662 | 777 | - | - | - | - | - | - |
$8,337 198,417 kWh |
$4,662 777 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $1,386 Cost: $3,248 |
$1,386 | 32,532 | - | - | - | - | - | - | - | - |
$1,386 32,532 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $1,928 Cost: $320 |
$1,928 | 45,428 | - | - | - | - | - | - | - | - |
$1,928 45,428 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $800 Cost: $1,000 |
- | - | - | - | - | - | $800 | 2,840 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$800 2,840 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.7196 USE RE-USABLE FILTERS |
Savings: $1,373 Cost: $1,440 |
- | - | - | - | - | - | - | 100 | $1,373 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- 100 lb |
$1,373 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $38,486 Cost: $50,903 |
$19,399 | 458,675 | $4,662 | 777 | $12,252 | 3,003 | $800 | 2,940 | $1,373 | - | $19,399 458,675 kWh |
$4,662 777 kW-months/year |
$12,252 3,003 MMBtu |
$800 2,940 lb |
$1,373 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $25,251 Cost: $43,220 |
$8,337 | 198,417 | $4,662 | 777 | $12,252 | 3,003 | - | - | - | - | $8,337 198,417 kWh |
$4,662 777 kW-months/year |
$12,252 3,003 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes |