Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 1997 |
Principal Product | furniture |
NAICS | n/a |
SIC | 2515 - Mattresses And Bedsprings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 350 |
Plant Area (Sq.Ft.) | 430,000 |
Annual Production | 93,740 Pieces |
Production Hrs. Annual | 2,000 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $78,288 | 2,306,272 | kWh | $0.03 |
Electricity Demand | $79,576 | 9,369 | kW-months/year | $8.49 |
Electricity Fees | $(-44) | - | $ | - |
Natural Gas | $37,974 | 5,617 | MMBtu | $6.76 |
TOTAL ENERGY COSTS | $276,234 | |||
RECOMMENDED SAVINGS* | $114,398 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $23,928 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $1,444 Cost: $132 |
$610 | 20,223 | $834 | 91 | - | - | - | - | - | - | - | - | - | - | - | - |
$610 20,223 kWh |
$834 91 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,963 Cost: $5,372 |
- | - | - | - | $1,963 | 437 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,963 437 MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $1,998 Cost: $1,500 |
- | - | $1,998 | - | - | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$1,998 - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $463 Cost: $880 |
$463 | 15,240 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$463 15,240 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $3,037 Cost: $722 |
$3,037 | 98,183 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$3,037 98,183 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $201 Cost: $287 |
- | - | - | - | $201 | 39 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$201 39 MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $16,230 Cost: $7,925 |
$3,513 | 115,768 | - | - | $12,717 | 2,832 | - | - | - | - | - | - | - | - | - | - |
$3,513 115,768 kWh |
- - kW-months/year |
$12,717 2,832 MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $20,100 Cost: - |
- | - | - | - | - | - | - | - | $20,100 | 82,000 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$20,100 82,000 lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS |
Savings: $2,556 Cost: - |
- | - | - | - | - | - | - | - | $756 | 84,000 | $(-300) | - | $2,100 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$756 84,000 lb |
$(-300) - $ |
$2,100 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $46,900 Cost: - |
- | - | - | - | - | - | - | - | $46,900 | 1,360,000 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$46,900 1,360,000 lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $18,007 Cost: $25,000 |
- | - | - | - | - | - | $1,600 | 220 | - | - | - | - | - | - | $16,407 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,600 220 gal |
- - lb |
- - $ |
- - $ |
$16,407 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.8112 COMBINE UTILITY METERS |
Savings: $1,499 Cost: $1,920 |
- | - | - | - | - | - | - | - | - | - | - | - | $1,499 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
$1,499 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $114,398 Cost: $43,738 |
$7,623 | 249,414 | $2,832 | 91 | $14,881 | 3,308 | $1,600 | 220 | $67,756 | 1,526,000 | $(-300) | - | $3,599 | - | $16,407 | - | $7,623 249,414 kWh |
$2,832 91 kW-months/year |
$14,881 3,308 MMBtu |
$1,600 220 gal |
$67,756 1,526,000 lb |
$(-300) - $ |
$3,599 - $ |
$16,407 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $23,928 Cost: $11,764 |
$4,123 | 135,991 | $2,832 | 91 | $12,918 | 2,871 | - | - | $756 | 84,000 | $(-300) | - | $3,599 | - | - | - | $4,123 135,991 kWh |
$2,832 91 kW-months/year |
$12,918 2,871 MMBtu |
- - gal |
$756 84,000 lb |
$(-300) - $ |
$3,599 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost |