Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 1998 |
Principal Product | Automotive Hoses and Connectors |
NAICS | n/a |
SIC | 3585 - Refrigeration And Heating Equipment |
Sales | $10,000,000-$50,000,000 |
# of Employees | 443 |
Plant Area (Sq.Ft.) | 172,000 |
Annual Production | 8,500,000 Pieces |
Production Hrs. Annual | 6,240 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $200,597 | 5,959,555 | kWh | $0.03 |
Electricity Demand | $116,030 | 12,709 | kW-months/year | $9.13 |
Electricity Fees | $7,384 | - | $ | - |
Natural Gas | $57,030 | 8,487 | MMBtu | $6.72 |
TOTAL ENERGY COSTS | $457,594 | |||
RECOMMENDED SAVINGS* | $154,667 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $42,268 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Personnel Changes | Water Consumption | One-time Revenue or Avoided Cost | Increase in Production | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Personnel Changes | Water Consumption | One-time Revenue or Avoided Cost | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | $ | $ | Tgal | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $19,058 Cost: $2,430 |
$18,776 | 557,737 | - | - | $282 | - | - | - | - | - | - | - | - | - | - | - |
$18,776 557,737 kWh |
- - kW-months/year |
$282 - $ |
- - Tgal |
- - $ |
- - Tgal |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $2,247 Cost: $4,950 |
- | - | - | - | $2,247 | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,247 - $ |
- - Tgal |
- - $ |
- - Tgal |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,048 Cost: $16,228 |
$2,867 | 85,287 | $1,121 | 117 | $60 | - | - | - | - | - | - | - | - | - | - | - |
$2,867 85,287 kWh |
$1,121 117 kW-months/year |
$60 - $ |
- - Tgal |
- - $ |
- - Tgal |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,881 Cost: $520 |
$5,796 | 169,109 | - | - | $85 | - | - | - | - | - | - | - | - | - | - | - |
$5,796 169,109 kWh |
- - kW-months/year |
$85 - $ |
- - Tgal |
- - $ |
- - Tgal |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $896 Cost: $472 |
$883 | 26,377 | - | - | $13 | - | - | - | - | - | - | - | - | - | - | - |
$883 26,377 kWh |
- - kW-months/year |
$13 - $ |
- - Tgal |
- - $ |
- - Tgal |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $2,782 Cost: $25 |
- | - | - | - | - | - | - | - | - | - | - | - | $2,782 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - $ |
- - Tgal |
$2,782 - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $107,455 Cost: $7,165 |
$(-2,681) | (-78,253) | - | - | - | - | $56,803 | 22,452,000 | - | - | $53,333 | - | - | - | - | - |
$(-2,681) (-78,253) kWh |
- - kW-months/year |
- - $ |
$56,803 22,452,000 Tgal |
- - $ |
$53,333 - Tgal |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.431 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY |
Savings: $2,652 Cost: $2,025 |
- | - | - | - | - | - | - | - | $(-5,616) | - | - | - | - | - | $8,268 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
$(-5,616) - $ |
- - Tgal |
- - $ |
$8,268 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.122 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS |
Savings: $9,648 Cost: $2,025 |
- | - | - | - | - | - | - | - | $(-5,616) | - | - | - | - | - | $15,264 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
$(-5,616) - $ |
- - Tgal |
- - $ |
$15,264 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $154,667 Cost: $35,840 |
$25,641 | 760,257 | $1,121 | 117 | $2,687 | - | $56,803 | 22,452,000 | $(-11,232) | - | $53,333 | - | $2,782 | - | $23,532 | - | $25,641 760,257 kWh |
$1,121 117 kW-months/year |
$2,687 - $ |
$56,803 22,452,000 Tgal |
$(-11,232) - $ |
$53,333 - Tgal |
$2,782 - $ |
$23,532 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $42,268 Cost: $11,975 |
$24,572 | 726,846 | - | - | $2,614 | - | - | - | $(-11,232) | - | - | - | $2,782 | - | $23,532 | - | $24,572 726,846 kWh |
- - kW-months/year |
$2,614 - $ |
- - Tgal |
$(-11,232) - $ |
- - Tgal |
$2,782 - $ |
$23,532 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | $ | $ | Tgal | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Personnel Changes | Water Consumption | One-time Revenue or Avoided Cost | Increase in Production | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Personnel Changes | Water Consumption | One-time Revenue or Avoided Cost | Increase in Production |