Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 1998 |
Principal Product | Prepared Poultry |
NAICS | n/a |
SIC | 2015 - Poultry Slaughtering And Processing |
Sales | $10,000,000-$50,000,000 |
# of Employees | 160 |
Plant Area (Sq.Ft.) | 37,800 |
Annual Production | 20,800,000 Pounds |
Production Hrs. Annual | 7,488 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $130,680 | 2,938,746 | kWh | $0.04 |
Electricity Demand | $28,623 | 6,365 | kW-months/year | $4.50 |
Electricity Fees | $(-14,507) | - | $ | - |
TOTAL ENERGY COSTS | $179,178 | |||
RECOMMENDED SAVINGS* | $15,999 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $7,233 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,761 Cost: $6,971 |
$2,697 | 85,580 | $531 | 118 | $(-467) | - | - | - | - | - | - | - | - | - |
$2,697 85,580 kWh |
$531 118 kW-months/year |
$(-467) - $ |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,888 Cost: $3,952 |
- | - | - | - | - | - | $2,888 | 1,086 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$2,888 1,086 MMBtu |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $125 Cost: $236 |
$151 | 4,689 | - | - | $(-26) | - | - | - | - | - | - | - | - | - |
$151 4,689 kWh |
- - kW-months/year |
$(-26) - $ |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $3,255 Cost: - |
- | - | - | - | - | - | - | - | - | - | $477 | - | $2,778 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
$477 - $ |
$2,778 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4151 MINIMIZE WATER USAGE |
Savings: $279 Cost: $10 |
- | - | - | - | - | - | - | - | $279 | 506,668 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$279 506,668 Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $5,878 Cost: $14,990 |
$1,246 | 47,773 | $342 | 76 | - | - | - | - | - | - | $1,080 | - | $3,210 | - |
$1,246 47,773 kWh |
$342 76 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
$1,080 - $ |
$3,210 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES |
Savings: $813 Cost: $324 |
- | - | - | - | $813 | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$813 - $ |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $15,999 Cost: $26,483 |
$4,094 | 138,042 | $873 | 194 | $320 | - | $2,888 | 1,086 | $279 | 506,668 | $1,557 | - | $5,988 | - | $4,094 138,042 kWh |
$873 194 kW-months/year |
$320 - $ |
$2,888 1,086 MMBtu |
$279 506,668 Tgal |
$1,557 - $ |
$5,988 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $7,233 Cost: $7,541 |
$2,848 | 90,269 | $531 | 118 | $320 | - | - | - | $279 | 506,668 | $477 | - | $2,778 | - | $2,848 90,269 kWh |
$531 118 kW-months/year |
$320 - $ |
- - MMBtu |
$279 506,668 Tgal |
$477 - $ |
$2,778 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Personnel Changes | One-time Revenue or Avoided Cost |