Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 2001 |
Principal Product | Plastic Battery Components |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 225 |
Plant Area (Sq.Ft.) | 150,000 |
Annual Production | 15,000,000 Pounds |
Production Hrs. Annual | 7,488 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $630,882 | 19,315,200 | kWh | $0.03 |
Electricity Demand | $366,710 | 37,315 | kW-months/year | $9.83 |
Electricity Fees | $15,172 | - | $ | - |
Natural Gas | $34,153 | 6,189 | MMBtu | $5.52 |
TOTAL ENERGY COSTS | $1,074,117 | |||
RECOMMENDED SAVINGS* | $50,417 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $22,170 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Other Liquid (haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Other Liquid (haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | gal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $14,770 Cost: $20,746 |
$8,791 | 269,569 | $5,761 | 565 | $218 | - | - | - | - | - | - | - |
$8,791 269,569 kWh |
$5,761 565 kW-months/year |
$218 - $ |
- - MMBtu |
- - Tgal |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $5,454 Cost: $9,024 |
$5,373 | 164,779 | - | - | $81 | - | - | - | - | - | - | - |
$5,373 164,779 kWh |
- - kW-months/year |
$81 - $ |
- - MMBtu |
- - Tgal |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $4,687 Cost: $6,580 |
$2,946 | 90,349 | - | - | $45 | - | $1,696 | 343 | - | - | - | - |
$2,946 90,349 kWh |
- - kW-months/year |
$45 - $ |
$1,696 343 MMBtu |
- - Tgal |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $633 Cost: $888 |
$588 | 18,027 | $36 | 4 | $9 | - | - | - | - | - | - | - |
$588 18,027 kWh |
$36 4 kW-months/year |
$9 - $ |
- - MMBtu |
- - Tgal |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE |
Savings: $292 Cost: $591 |
$288 | 8,822 | - | - | $4 | - | - | - | - | - | - | - |
$288 8,822 kWh |
- - kW-months/year |
$4 - $ |
- - MMBtu |
- - Tgal |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $12,504 Cost: $18,000 |
- | - | - | - | $12,504 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$12,504 - $ |
- - MMBtu |
- - Tgal |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.6124 BURN WASTE OIL FOR HEAT |
Savings: $3,044 Cost: $3,074 |
- | - | - | - | - | - | $1,762 | 343 | - | - | $1,282 | 3,060 |
- - kWh |
- - kW-months/year |
- - $ |
$1,762 343 MMBtu |
- - Tgal |
$1,282 3,060 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES |
Savings: $9,033 Cost: $25 |
- | - | - | - | - | - | - | - | $9,033 | 7,226,600 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$9,033 7,226,600 Tgal |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $50,417 Cost: $58,928 |
$17,986 | 551,546 | $5,797 | 569 | $12,861 | - | $3,458 | 686 | $9,033 | 7,226,600 | $1,282 | 3,060 | $17,986 551,546 kWh |
$5,797 569 kW-months/year |
$12,861 - $ |
$3,458 686 MMBtu |
$9,033 7,226,600 Tgal |
$1,282 3,060 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $22,170 Cost: $18,913 |
$588 | 18,027 | $36 | 4 | $12,513 | - | - | - | $9,033 | 7,226,600 | - | - | $588 18,027 kWh |
$36 4 kW-months/year |
$12,513 - $ |
- - MMBtu |
$9,033 7,226,600 Tgal |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | gal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Other Liquid (haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Other Liquid (haz) |