Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 2002 |
Principal Product | Cardboard containers |
NAICS | n/a |
SIC | 2653 - Corrugated And Solid Fiber Boxes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 102 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 536,000 Bushels |
Production Hrs. Annual | 5,720 |
Location (State) | TN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $143,430 | 4,328,000 | kWh | $0.03 |
Electricity Demand | $105,170 | 11,000 | kW-months/year | $9.56 |
Electricity Fees | $3,839 | - | $ | - |
Natural Gas | $296,477 | 40,669 | MMBtu | $7.29 |
TOTAL ENERGY COSTS | $574,305 | |||
RECOMMENDED SAVINGS* | $71,103 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Other Liquid (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Other Liquid (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | gal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $28,045 Cost: $7,508 |
- | - | - | - | - | - | $28,045 | 3,790 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$28,045 3,790 MMBtu |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $8,945 Cost: $8,000 |
- | - | - | - | - | - | $8,945 | 1,209 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$8,945 1,209 MMBtu |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $8,351 Cost: $23,103 |
$4,926 | 148,625 | $3,302 | 312 | $123 | - | - | - | - | - |
$4,926 148,625 kWh |
$3,302 312 kW-months/year |
$123 - $ |
- - MMBtu |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,335 Cost: $189 |
$5,256 | 158,579 | - | - | $79 | - | - | - | - | - |
$5,256 158,579 kWh |
- - kW-months/year |
$79 - $ |
- - MMBtu |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7293 INSTALL DRY SPRINKLER SYSTEM OR OTHER METHOD TO REDUCE HEATING REQUIREMENTS |
Savings: $5,141 Cost: $971 |
- | - | - | - | - | - | $5,141 | 714 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$5,141 714 MMBtu |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $3,757 Cost: $4,120 |
$2,216 | 66,859 | $1,486 | 140 | $55 | - | - | - | - | - |
$2,216 66,859 kWh |
$1,486 140 kW-months/year |
$55 - $ |
- - MMBtu |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $2,925 Cost: $80 |
$891 | 26,883 | $1,991 | 188 | $43 | - | - | - | - | - |
$891 26,883 kWh |
$1,991 188 kW-months/year |
$43 - $ |
- - MMBtu |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,720 Cost: $233 |
$724 | 21,848 | $971 | 92 | $25 | - | - | - | - | - |
$724 21,848 kWh |
$971 92 kW-months/year |
$25 - $ |
- - MMBtu |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,327 Cost: $1,088 |
$693 | 20,917 | $614 | 58 | $20 | - | - | - | - | - |
$693 20,917 kWh |
$614 58 kW-months/year |
$20 - $ |
- - MMBtu |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $867 Cost: $708 |
$854 | 25,774 | - | - | $13 | - | - | - | - | - |
$854 25,774 kWh |
- - kW-months/year |
$13 - $ |
- - MMBtu |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $413 Cost: $60 |
$216 | 6,521 | $191 | 18 | $6 | - | - | - | - | - |
$216 6,521 kWh |
$191 18 kW-months/year |
$6 - $ |
- - MMBtu |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $257 Cost: $250 |
$114 | 3,442 | $139 | 13 | $4 | - | - | - | - | - |
$114 3,442 kWh |
$139 13 kW-months/year |
$4 - $ |
- - MMBtu |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.7122 DISCONNECT BALLASTS |
Savings: $213 Cost: $150 |
$126 | 3,792 | $84 | 8 | $3 | - | - | - | - | - |
$126 3,792 kWh |
$84 8 kW-months/year |
$3 - $ |
- - MMBtu |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 3.6124 BURN WASTE OIL FOR HEAT |
Savings: $3,807 Cost: $5,761 |
- | - | - | - | - | - | $1,287 | 148 | $2,520 | 1,320 |
- - kWh |
- - kW-months/year |
- - $ |
$1,287 148 MMBtu |
$2,520 1,320 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $71,103 Cost: $52,221 |
$16,016 | 483,240 | $8,778 | 829 | $371 | - | $43,418 | 5,861 | $2,520 | 1,320 | $16,016 483,240 kWh |
$8,778 829 kW-months/year |
$371 - $ |
$43,418 5,861 MMBtu |
$2,520 1,320 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | gal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Other Liquid (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Other Liquid (non-haz) |