Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 2004 |
Principal Product | Shower Curtains |
NAICS | 314120 - Curtain and Linen Mills |
SIC | 2391 - Curtains And Draperies |
Sales | $100,000,000-$500,000,000 |
# of Employees | 380 |
Plant Area (Sq.Ft.) | 450,000 |
Annual Production | 5,000,000 Pieces |
Production Hrs. Annual | 5,824 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $397,171 | 8,844,040 | kWh | $0.04 |
Electricity Demand | $69,650 | 21,602 | kW-months/year | $3.22 |
Electricity Fees | $96,175 | - | $ | - |
Natural Gas | $62,305 | 8,007 | MMBtu | $7.78 |
TOTAL ENERGY COSTS | $686,640 | |||
RECOMMENDED SAVINGS* | $102,982 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $50,275 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $42,786 Cost: $4,860 |
$34,598 | 839,961 | - | - | $8,188 | - | - | - |
$34,598 839,961 kWh |
- - kW-months/year |
$8,188 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8112 COMBINE UTILITY METERS |
Savings: $30,379 Cost: $200 |
- | - | - | - | $30,379 | - | - | - |
- - kWh |
- - kW-months/year |
$30,379 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $12,381 Cost: $1,000 |
$10,011 | 243,055 | - | - | $2,370 | - | - | - |
$10,011 243,055 kWh |
- - kW-months/year |
$2,370 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $5,138 Cost: $1,000 |
$4,155 | 100,865 | - | - | $983 | - | - | - |
$4,155 100,865 kWh |
- - kW-months/year |
$983 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,485 Cost: $247 |
$3,626 | 88,039 | - | - | $859 | - | - | - |
$3,626 88,039 kWh |
- - kW-months/year |
$859 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $3,141 Cost: - |
- | - | $2,534 | 792 | $607 | - | - | - |
- - kWh |
$2,534 792 kW-months/year |
$607 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $3,004 Cost: - |
- | - | $2,420 | 757 | $584 | - | - | - |
- - kWh |
$2,420 757 kW-months/year |
$584 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7229 AIR CONDITION ONLY SPACE NECESSARY |
Savings: $1,009 Cost: $400 |
$538 | 13,075 | $276 | 86 | $195 | - | - | - |
$538 13,075 kWh |
$276 86 kW-months/year |
$195 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES |
Savings: $659 Cost: $100 |
- | - | - | - | - | - | $659 | - |
- - kWh |
- - kW-months/year |
- - $ |
$659 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $102,982 Cost: $7,807 |
$52,928 | 1,284,995 | $5,230 | 1,635 | $44,165 | - | $659 | - | $52,928 1,284,995 kWh |
$5,230 1,635 kW-months/year |
$44,165 - $ |
$659 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $50,275 Cost: $5,107 |
$38,224 | 928,000 | $2,420 | 757 | $9,631 | - | - | - | $38,224 928,000 kWh |
$2,420 757 kW-months/year |
$9,631 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes |