Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 2004 |
Principal Product | Furniture/bedding fiber |
NAICS | 337910 - Mattress Manufacturing |
SIC | 2515 - Mattresses And Bedsprings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 87 |
Plant Area (Sq.Ft.) | 170,000 |
Annual Production | 18,000,000 Pounds |
Production Hrs. Annual | 5,500 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $142,234 | 3,974,160 | kWh | $0.04 |
Electricity Demand | $76,459 | 9,830 | kW-months/year | $7.78 |
Electricity Fees | $3,496 | - | $ | - |
Natural Gas | $163,103 | 31,639 | MMBtu | $5.16 |
TOTAL ENERGY COSTS | $390,157 | |||
RECOMMENDED SAVINGS* | $104,033 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,164 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT |
Savings: $82,017 Cost: $6,780 |
- | - | - | - | - | - | $82,017 | 15,907 |
- - kWh |
- - kW-months/year |
- - $ |
$82,017 15,907 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $8,496 Cost: $15,583 |
$5,287 | 159,530 | $3,083 | 348 | $126 | - | - | - |
$5,287 159,530 kWh |
$3,083 348 kW-months/year |
$126 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1224 REPLACE BOILER |
Savings: $6,523 Cost: $4,642 |
- | - | - | - | - | - | $6,523 | 1,265 |
- - kWh |
- - kW-months/year |
- - $ |
$6,523 1,265 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $3,354 Cost: $1,036 |
$3,304 | 99,705 | - | - | $50 | - | - | - |
$3,304 99,705 kWh |
- - kW-months/year |
$50 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,071 Cost: $156 |
$2,040 | 61,571 | - | - | $31 | - | - | - |
$2,040 61,571 kWh |
- - kW-months/year |
$31 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,263 Cost: $1,542 |
- | - | - | - | - | - | $1,263 | 245 |
- - kWh |
- - kW-months/year |
- - $ |
$1,263 245 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $216 Cost: $355 |
$213 | 6,422 | - | - | $3 | - | - | - |
$213 6,422 kWh |
- - kW-months/year |
$3 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7122 DISCONNECT BALLASTS |
Savings: $93 Cost: $180 |
$56 | 1,683 | $35 | 4 | $2 | - | - | - |
$56 1,683 kWh |
$35 4 kW-months/year |
$2 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $104,033 Cost: $30,274 |
$10,900 | 328,911 | $3,118 | 352 | $212 | - | $89,803 | 17,417 | $10,900 328,911 kWh |
$3,118 352 kW-months/year |
$212 - $ |
$89,803 17,417 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,164 Cost: $336 |
$2,096 | 63,254 | $35 | 4 | $33 | - | - | - | $2,096 63,254 kWh |
$35 4 kW-months/year |
$33 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |