Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 2004 |
Principal Product | Electrostatic coatings |
NAICS | 332812 - Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers |
SIC | 3479 - Metal Coating And Allied Services |
Sales | $50,000,000-$100,000,000 |
# of Employees | 38 |
Plant Area (Sq.Ft.) | 98,600 |
Annual Production | 152,000 Pieces |
Production Hrs. Annual | 6,000 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $171,626 | 4,126,800 | kWh | $0.04 |
Electricity Demand | $35,313 | 8,202 | kW-months/year | $4.31 |
Electricity Fees | $55,021 | - | $ | - |
Natural Gas | $130,493 | 12,993 | MMBtu | $10.04 |
TOTAL ENERGY COSTS | $408,691 | |||
RECOMMENDED SAVINGS* | $27,105 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $12,928 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $11,003 Cost: $10,413 |
- | - | - | - | - | - | $11,003 | 1,096 |
- - kWh |
- - kW-months/year |
- - $ |
$11,003 1,096 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,867 Cost: $11,496 |
$4,279 | 128,385 | $900 | 257 | $1,688 | - | - | - |
$4,279 128,385 kWh |
$900 257 kW-months/year |
$1,688 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,256 Cost: $230 |
$2,412 | 72,377 | - | - | $844 | - | - | - |
$2,412 72,377 kWh |
- - kW-months/year |
$844 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $2,835 Cost: $4,800 |
- | - | - | - | - | - | $2,835 | 282 |
- - kWh |
- - kW-months/year |
- - $ |
$2,835 282 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,270 Cost: $1,731 |
- | - | - | - | - | - | $2,270 | 226 |
- - kWh |
- - kW-months/year |
- - $ |
$2,270 226 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $535 Cost: $125 |
$321 | 9,625 | $84 | 24 | $130 | - | - | - |
$321 9,625 kWh |
$84 24 kW-months/year |
$130 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $207 Cost: $355 |
$153 | 4,602 | - | - | $54 | - | - | - |
$153 4,602 kWh |
- - kW-months/year |
$54 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $132 Cost: $346 |
$97 | 2,924 | - | - | $35 | - | - | - |
$97 2,924 kWh |
- - kW-months/year |
$35 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $27,105 Cost: $29,496 |
$7,262 | 217,913 | $984 | 281 | $2,751 | - | $16,108 | 1,604 | $7,262 217,913 kWh |
$984 281 kW-months/year |
$2,751 - $ |
$16,108 1,604 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $12,928 Cost: $13,582 |
$7,012 | 210,387 | $984 | 281 | $2,662 | - | $2,270 | 226 | $7,012 210,387 kWh |
$984 281 kW-months/year |
$2,662 - $ |
$2,270 226 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |