Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 2004 |
Principal Product | Cardboard Boxes |
NAICS | 322211 - Corrugated and Solid Fiber Box Manufacturing |
SIC | 2653 - Corrugated And Solid Fiber Boxes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 250,000 |
Annual Production | 700,000 Thousand Feet |
Production Hrs. Annual | 6,240 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $247,849 | 5,500,500 | kWh | $0.05 |
Electricity Demand | $41,389 | 12,773 | kW-months/year | $3.24 |
Electricity Fees | $95,035 | - | $ | - |
Natural Gas | $319,960 | 45,973 | MMBtu | $6.96 |
TOTAL ENERGY COSTS | $716,553 | |||
RECOMMENDED SAVINGS* | $59,706 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $23,624 Cost: $25,372 |
$12,698 | 308,268 | $1,895 | 593 | $9,031 | - | - | - |
$12,698 308,268 kWh |
$1,895 593 kW-months/year |
$9,031 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $15,290 Cost: $15,000 |
- | - | - | - | - | - | $15,290 | 2,199 |
- - kWh |
- - kW-months/year |
- - $ |
$15,290 2,199 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $6,881 Cost: $3,275 |
- | - | - | - | - | - | $6,881 | 990 |
- - kWh |
- - kW-months/year |
- - $ |
$6,881 990 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $4,978 Cost: $2,968 |
$2,966 | 72,002 | - | - | $2,012 | - | - | - |
$2,966 72,002 kWh |
- - kW-months/year |
$2,012 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $3,530 Cost: $1,992 |
$1,894 | 45,992 | $288 | 90 | $1,348 | - | - | - |
$1,894 45,992 kWh |
$288 90 kW-months/year |
$1,348 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,883 Cost: - |
$1,122 | 27,232 | - | - | $761 | - | - | - |
$1,122 27,232 kWh |
- - kW-months/year |
$761 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $1,491 Cost: $19 |
- | - | - | - | - | - | $1,491 | 214 |
- - kWh |
- - kW-months/year |
- - $ |
$1,491 214 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,148 Cost: $3,031 |
$617 | 14,976 | $93 | 29 | $438 | - | - | - |
$617 14,976 kWh |
$93 29 kW-months/year |
$438 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $881 Cost: $66 |
$432 | 10,483 | $128 | 40 | $321 | - | - | - |
$432 10,483 kWh |
$128 40 kW-months/year |
$321 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $59,706 Cost: $51,723 |
$19,729 | 478,953 | $2,404 | 752 | $13,911 | - | $23,662 | 3,403 | $19,729 478,953 kWh |
$2,404 752 kW-months/year |
$13,911 - $ |
$23,662 3,403 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |