Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 2004 |
Principal Product | Lumber |
NAICS | 321113 - Sawmills |
SIC | 2421 - Sawmills And Planing Mills, General |
Sales | $50,000,000-$100,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 250,000 |
Annual Production | 235,000,000 Thousand Feet |
Production Hrs. Annual | 5,000 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,056,226 | 30,615,254 | kWh | $0.03 |
Electricity Demand | $379,562 | 65,157 | kW-months/year | $5.83 |
Electricity Fees | $444,194 | - | $ | - |
TOTAL ENERGY COSTS | $1,903,227 | |||
RECOMMENDED SAVINGS* | $115,085 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $44,456 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $56,439 Cost: $32,850 |
$27,771 | 804,960 | $6,197 | 1,104 | $22,471 | - |
$27,771 804,960 kWh |
$6,197 1,104 kW-months/year |
$22,471 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE |
Savings: $15,412 Cost: $1,518 |
$6,347 | 183,961 | $3,396 | 605 | $5,669 | - |
$6,347 183,961 kWh |
$3,396 605 kW-months/year |
$5,669 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $14,422 Cost: $20,370 |
$6,412 | 185,861 | $2,526 | 450 | $5,484 | - |
$6,412 185,861 kWh |
$2,526 450 kW-months/year |
$5,484 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $12,889 Cost: $406 |
$7,369 | 213,587 | - | - | $5,520 | - |
$7,369 213,587 kWh |
- - kW-months/year |
$5,520 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $9,490 Cost: $6,318 |
$5,426 | 157,271 | - | - | $4,064 | - |
$5,426 157,271 kWh |
- - kW-months/year |
$4,064 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $3,878 Cost: $3,710 |
$2,217 | 64,262 | - | - | $1,661 | - |
$2,217 64,262 kWh |
- - kW-months/year |
$1,661 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $918 Cost: $2,125 |
$525 | 15,215 | - | - | $393 | - |
$525 15,215 kWh |
- - kW-months/year |
$393 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $822 Cost: $1,969 |
$405 | 11,730 | $90 | 16 | $327 | - |
$405 11,730 kWh |
$90 16 kW-months/year |
$327 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE |
Savings: $815 Cost: $444 |
$466 | 13,509 | - | - | $349 | - |
$466 13,509 kWh |
- - kW-months/year |
$349 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $115,085 Cost: $69,710 |
$56,938 | 1,650,356 | $12,209 | 2,175 | $45,938 | - | $56,938 1,650,356 kWh |
$12,209 2,175 kW-months/year |
$45,938 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $44,456 Cost: $24,863 |
$21,119 | 612,133 | $5,922 | 1,055 | $17,415 | - | $21,119 612,133 kWh |
$5,922 1,055 kW-months/year |
$17,415 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees |