Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 2006 |
Principal Product | small gasoline engines |
NAICS | 336310 - Motor Vehicle Gasoline Engine and Engine Parts Manufacturing |
SIC | 3714 - Motor Vehicle Parts And Accessories |
Sales | $10,000,000-$50,000,000 |
# of Employees | 278 |
Plant Area (Sq.Ft.) | 186,277 |
Annual Production | 1,500,000 Pieces |
Production Hrs. Annual | 5,000 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $207,228 | 7,025,338 | kWh | $0.03 |
Electricity Demand | $127,248 | 15,647 | kW-months/year | $8.13 |
Electricity Fees | $27,323 | - | $ | - |
Natural Gas | $117,309 | 13,504 | MMBtu | $8.69 |
TOTAL ENERGY COSTS | $479,108 | |||
RECOMMENDED SAVINGS* | $26,997 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $15,615 Cost: $42,772 |
$10,430 | 298,773 | $7,736 | 717 | $(-2,551) | - |
$10,430 298,773 kWh |
$7,736 717 kW-months/year |
$(-2,551) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $5,962 Cost: $54 |
$3,979 | 114,000 | $2,956 | 274 | $(-973) | - |
$3,979 114,000 kWh |
$2,956 274 kW-months/year |
$(-973) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $1,395 Cost: $100 |
$932 | 26,710 | $691 | 64 | $(-228) | - |
$932 26,710 kWh |
$691 64 kW-months/year |
$(-228) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $1,133 Cost: $2,724 |
$1,321 | 37,844 | - | - | $(-188) | - |
$1,321 37,844 kWh |
- - kW-months/year |
$(-188) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $904 Cost: $148 |
$469 | 13,427 | $583 | 54 | $(-148) | - |
$469 13,427 kWh |
$583 54 kW-months/year |
$(-148) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $743 Cost: $2,475 |
$432 | 12,377 | $432 | 40 | $(-121) | - |
$432 12,377 kWh |
$432 40 kW-months/year |
$(-121) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,245 Cost: $223 |
$1,453 | 41,617 | - | - | $(-208) | - |
$1,453 41,617 kWh |
- - kW-months/year |
$(-208) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $26,997 Cost: $48,496 |
$19,016 | 544,748 | $12,398 | 1,149 | $(-4,417) | - | $19,016 544,748 kWh |
$12,398 1,149 kW-months/year |
$(-4,417) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees |