Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 2006 |
Principal Product | copper tubing |
NAICS | 331420 - Copper Rolling, Drawing, Extruding, and Alloying |
SIC | 3351 - Copper Rolling And Drawing |
Sales | $100,000,000-$500,000,000 |
# of Employees | 370 |
Plant Area (Sq.Ft.) | 420,000 |
Annual Production | 220,000,000 Pounds |
Production Hrs. Annual | 8,736 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,478,582 | 57,293,550 | kWh | $0.03 |
Electricity Demand | $1,144,460 | 106,855 | kW-months/year | $10.71 |
Electricity Fees | $72,266 | - | $ | - |
Natural Gas | $5,434,615 | 59,357 | MMBtu | $91.56 |
TOTAL ENERGY COSTS | $8,129,923 | |||
RECOMMENDED SAVINGS* | $157,273 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,000 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3412 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR |
Savings: $93,222 Cost: $290,000 |
$56,522 | 2,102,755 | $35,322 | 3,480 | $1,378 | - |
$56,522 2,102,755 kWh |
$35,322 3,480 kW-months/year |
$1,378 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $47,448 Cost: $70,420 |
$30,781 | 1,145,111 | $15,966 | 1,573 | $701 | - |
$30,781 1,145,111 kWh |
$15,966 1,573 kW-months/year |
$701 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $11,175 Cost: $21,180 |
$11,010 | 409,602 | - | - | $165 | - |
$11,010 409,602 kWh |
- - kW-months/year |
$165 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,047 Cost: $10,811 |
$1,062 | 39,524 | $954 | 94 | $31 | - |
$1,062 39,524 kWh |
$954 94 kW-months/year |
$31 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,760 Cost: $172 |
$1,734 | 64,527 | - | - | $26 | - |
$1,734 64,527 kWh |
- - kW-months/year |
$26 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,240 Cost: $609 |
$704 | 26,208 | $518 | 51 | $18 | - |
$704 26,208 kWh |
$518 51 kW-months/year |
$18 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7229 AIR CONDITION ONLY SPACE NECESSARY |
Savings: $381 Cost: $240 |
$111 | 4,147 | $264 | 26 | $6 | - |
$111 4,147 kWh |
$264 26 kW-months/year |
$6 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $157,273 Cost: $393,432 |
$101,924 | 3,791,874 | $53,024 | 5,224 | $2,325 | - | $101,924 3,791,874 kWh |
$53,024 5,224 kW-months/year |
$2,325 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,000 Cost: $781 |
$2,438 | 90,735 | $518 | 51 | $44 | - | $2,438 90,735 kWh |
$518 51 kW-months/year |
$44 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees |