Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 2006 |
Principal Product | lighting |
NAICS | 335122 - Commercial, Industrial, and Institutional Electric Lighting Fixture Manufacturing |
SIC | 3646 - Commercial Lighting Fixtures |
Sales | $10,000,000-$50,000,000 |
# of Employees | 614 |
Plant Area (Sq.Ft.) | 470,000 |
Annual Production | 365,000 Pieces |
Production Hrs. Annual | 4,800 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $444,426 | 10,439,161 | kWh | $0.04 |
Electricity Demand | $83,578 | 21,991 | kW-months/year | $3.80 |
Electricity Fees | $342,422 | - | $ | - |
Natural Gas | $430,915 | 41,494 | MMBtu | $10.38 |
TOTAL ENERGY COSTS | $1,301,341 | |||
RECOMMENDED SAVINGS* | $292,053 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $218,683 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $183,533 Cost: $1,062 |
$177,994 | 534,067 | - | - | $5,539 | - |
$177,994 534,067 kWh |
- - kW-months/year |
$5,539 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $35,150 Cost: $123,600 |
$33,324 | 99,840 | $875 | 250 | $951 | - |
$33,324 99,840 kWh |
$875 250 kW-months/year |
$951 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $29,145 Cost: $4,200 |
$28,266 | 84,812 | - | - | $879 | - |
$28,266 84,812 kWh |
- - kW-months/year |
$879 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $27,793 Cost: $12,375 |
$26,347 | 79,054 | $693 | 198 | $753 | - |
$26,347 79,054 kWh |
$693 198 kW-months/year |
$753 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $16,432 Cost: $64,150 |
$15,102 | 45,314 | $952 | 272 | $378 | - |
$15,102 45,314 kWh |
$952 272 kW-months/year |
$378 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $292,053 Cost: $205,387 |
$281,033 | 843,087 | $2,520 | 720 | $8,500 | - | $281,033 843,087 kWh |
$2,520 720 kW-months/year |
$8,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $218,683 Cost: $124,662 |
$211,318 | 633,907 | $875 | 250 | $6,490 | - | $211,318 633,907 kWh |
$875 250 kW-months/year |
$6,490 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees |