Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 2006 |
Principal Product | Aircraft parts |
NAICS | 336413 - Other Aircraft Parts and Auxiliary Equipment Manufacturing |
SIC | 3728 - Aircraft Parts And Equipment, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 340 |
Plant Area (Sq.Ft.) | 400,000 |
Annual Production | 223,000 Pieces |
Production Hrs. Annual | 4,992 |
Location (State) | AR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $275,694 | 11,755,748 | kWh | $0.02 |
Electricity Demand | $78,216 | 24,970 | kW-months/year | $3.13 |
Electricity Fees | $33,818 | - | $ | - |
Natural Gas | $1,032,380 | 117,572 | MMBtu | $8.78 |
TOTAL ENERGY COSTS | $1,420,108 | |||
RECOMMENDED SAVINGS* | $38,586 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $35,519 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $17,310 Cost: $21,720 |
- | - | - | - | - | - | $17,310 | 1,982 |
- - kWh |
- - kW-months/year |
- - $ |
$17,310 1,982 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $12,625 Cost: $30,484 |
$6,821 | 495,707 | $4,815 | 681 | $989 | - | - | - |
$6,821 495,707 kWh |
$4,815 681 kW-months/year |
$989 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,037 Cost: $21,914 |
$1,441 | 104,744 | $1,357 | 192 | $239 | - | - | - |
$1,441 104,744 kWh |
$1,357 192 kW-months/year |
$239 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,153 Cost: $9,150 |
$1,029 | 74,785 | $1,124 | 159 | - | - | - | - |
$1,029 74,785 kWh |
$1,124 159 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.6124 BURN WASTE OIL FOR HEAT |
Savings: $1,477 Cost: $2,186 |
- | - | - | - | - | - | $1,477 | 123 |
- - kWh |
- - kW-months/year |
- - $ |
$1,477 123 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,070 Cost: $244 |
$986 | 71,683 | - | - | $84 | - | - | - |
$986 71,683 kWh |
- - kW-months/year |
$84 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $914 Cost: $4,882 |
$842 | 61,221 | - | - | $72 | - | - | - |
$842 61,221 kWh |
- - kW-months/year |
$72 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $38,586 Cost: $90,580 |
$11,119 | 808,140 | $7,296 | 1,032 | $1,384 | - | $18,787 | 2,105 | $11,119 808,140 kWh |
$7,296 1,032 kW-months/year |
$1,384 - $ |
$18,787 2,105 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $35,519 Cost: $76,548 |
$9,248 | 672,134 | $6,172 | 873 | $1,312 | - | $18,787 | 2,105 | $9,248 672,134 kWh |
$6,172 873 kW-months/year |
$1,312 - $ |
$18,787 2,105 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |