Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 2007 |
Principal Product | Venetian Blind Components |
NAICS | 337920 - Blind and Shade Manufacturing |
SIC | 2591 - Drapery Hardware & Blinds & Shades |
Sales | $10,000,000-$50,000,000 |
# of Employees | 163 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 240,000 Units |
Production Hrs. Annual | 6,240 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $303,195 | 4,487,312 | kWh | $0.07 |
Electricity Demand | $106,572 | 9,689 | kW-months/year | $11.00 |
Electricity Fees | $1,458 | - | $ | - |
Natural Gas | $328,659 | 26,351 | MMBtu | $12.47 |
TOTAL ENERGY COSTS | $739,884 | |||
RECOMMENDED SAVINGS* | $42,409 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $4,470 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $29,634 Cost: $62,998 |
$18,924 | 441,112 | $10,710 | 848 | - | - |
$18,924 441,112 kWh |
$10,710 848 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,986 Cost: $23,207 |
$2,801 | 65,302 | $2,185 | 173 | - | - |
$2,801 65,302 kWh |
$2,185 173 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,166 Cost: $176 |
$2,166 | 50,474 | - | - | - | - |
$2,166 50,474 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6214 SHUT OFF PILOTS IN STANDBY EQUIPMENT |
Savings: $1,669 Cost: $185 |
- | - | - | - | $1,669 | 136 |
- - kWh |
- - kW-months/year |
$1,669 136 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,304 Cost: $2,700 |
$1,318 | 30,713 | $986 | 78 | - | - |
$1,318 30,713 kWh |
$986 78 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.6124 BURN WASTE OIL FOR HEAT |
Savings: $1,265 Cost: $2,186 |
- | - | - | - | $1,265 | 86 |
- - kWh |
- - kW-months/year |
$1,265 86 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $385 Cost: $476 |
- | - | - | - | $385 | 31 |
- - kWh |
- - kW-months/year |
$385 31 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $42,409 Cost: $91,928 |
$25,209 | 587,601 | $13,881 | 1,099 | $3,319 | 253 | $25,209 587,601 kWh |
$13,881 1,099 kW-months/year |
$3,319 253 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $4,470 Cost: $2,876 |
$3,484 | 81,187 | $986 | 78 | - | - | $3,484 81,187 kWh |
$986 78 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |