Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 2008 |
Principal Product | Meat |
NAICS | 311611 - Animal (except Poultry) Slaughtering |
SIC | 2011 - Meat Packing Plants |
Sales | $10,000,000-$50,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 53,000 |
Annual Production | 7,000,000 Pounds |
Production Hrs. Annual | 4,160 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $282,140 | 3,897,120 | kWh | $0.07 |
Electricity Demand | $53,335 | 9,877 | kW-months/year | $5.40 |
Electricity Fees | $340,507 | - | $ | - |
Natural Gas | $240,114 | 23,378 | MMBtu | $10.27 |
TOTAL ENERGY COSTS | $916,096 | |||
RECOMMENDED SAVINGS* | $42,203 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $29,408 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $19,471 Cost: $24,719 |
$17,385 | 242,981 | $1,798 | 333 | $288 | - | - | - |
$17,385 242,981 kWh |
$1,798 333 kW-months/year |
$288 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $9,208 Cost: $156 |
- | - | - | - | - | - | $9,208 | 900 |
- - kWh |
- - kW-months/year |
- - $ |
$9,208 900 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $6,992 Cost: $8,100 |
- | - | - | - | - | - | $6,992 | 681 |
- - kWh |
- - kW-months/year |
- - $ |
$6,992 681 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $4,031 Cost: $7,308 |
$3,971 | 55,500 | - | - | $60 | - | - | - |
$3,971 55,500 kWh |
- - kW-months/year |
$60 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,772 Cost: $236 |
$1,747 | 24,433 | - | - | $25 | - | - | - |
$1,747 24,433 kWh |
- - kW-months/year |
$25 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $411 Cost: $1,800 |
$403 | 5,615 | - | - | $8 | - | - | - |
$403 5,615 kWh |
- - kW-months/year |
$8 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $318 Cost: $1,050 |
$216 | 3,020 | $97 | 18 | $5 | - | - | - |
$216 3,020 kWh |
$97 18 kW-months/year |
$5 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $42,203 Cost: $43,369 |
$23,722 | 331,549 | $1,895 | 351 | $386 | - | $16,200 | 1,581 | $23,722 331,549 kWh |
$1,895 351 kW-months/year |
$386 - $ |
$16,200 1,581 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $29,408 Cost: $27,725 |
$18,004 | 251,616 | $1,895 | 351 | $301 | - | $9,208 | 900 | $18,004 251,616 kWh |
$1,895 351 kW-months/year |
$301 - $ |
$9,208 900 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |