Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 2010 |
Principal Product | Heat Exchangers |
NAICS | 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
SIC | 3585 - Refrigeration And Heating Equipment |
Sales | $5,000,000-$10,000,000 |
# of Employees | 49 |
Plant Area (Sq.Ft.) | 85,000 |
Annual Production | 18,000 Pieces |
Production Hrs. Annual | 6,000 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $128,095 | 2,129,632 | kWh | $0.06 |
Electricity Demand | $14,756 | 11,625 | kW-months/year | $1.27 |
Electricity Fees | $63,137 | - | $ | - |
Natural Gas | $23,817 | 2,880 | MMBtu | $8.27 |
TOTAL ENERGY COSTS | $229,805 | |||
RECOMMENDED SAVINGS* | $31,907 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $16,588 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $12,903 Cost: $31,050 |
$11,286 | 184,008 | $1,426 | 386 | $191 | - |
$11,286 184,008 kWh |
$1,426 386 kW-months/year |
$191 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $11,920 Cost: $140 |
$10,089 | 164,493 | $1,655 | 448 | $176 | - |
$10,089 164,493 kWh |
$1,655 448 kW-months/year |
$176 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,685 Cost: $389 |
$3,630 | 59,192 | - | - | $55 | - |
$3,630 59,192 kWh |
- - kW-months/year |
$55 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,399 Cost: $671 |
$3,348 | 54,588 | - | - | $51 | - |
$3,348 54,588 kWh |
- - kW-months/year |
$51 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $31,907 Cost: $32,250 |
$28,353 | 462,281 | $3,081 | 834 | $473 | - | $28,353 462,281 kWh |
$3,081 834 kW-months/year |
$473 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $16,588 Cost: $31,439 |
$14,916 | 243,200 | $1,426 | 386 | $246 | - | $14,916 243,200 kWh |
$1,426 386 kW-months/year |
$246 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees |