Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 2011 |
Principal Product | Lumber |
NAICS | 321999 - All Other Miscellaneous Wood Product Manufacturing |
SIC | 2421 - Sawmills And Planing Mills, General |
Sales | $10,000,000-$50,000,000 |
# of Employees | 98 |
Plant Area (Sq.Ft.) | 150,000 |
Annual Production | 25,000 Thousand Feet |
Production Hrs. Annual | 2,550 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $269,910 | 5,478,711 | kWh | $0.05 |
Electricity Demand | $331,476 | 18,786 | kW-months/year | $17.64 |
Electricity Fees | $(-38,518) | - | $ | - |
Wood | $172,835 | 310,855 | MMBtu | $0.56 |
TOTAL ENERGY COSTS | $735,703 | |||
RECOMMENDED SAVINGS* | $86,369 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $27,537 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3412 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR |
Savings: $57,503 Cost: $375,001 |
$31,862 | 663,800 | $57,348 | 3,240 | $1,338 | - | $(-33,045) | - |
$31,862 663,800 kWh |
$57,348 3,240 kW-months/year |
$1,338 - $ |
$(-33,045) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $13,956 Cost: $12,825 |
$4,238 | 88,283 | $9,452 | 534 | $266 | - | - | - |
$4,238 88,283 kWh |
$9,452 534 kW-months/year |
$266 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,534 Cost: $285 |
$2,534 | 51,969 | - | - | - | - | - | - |
$2,534 51,969 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,632 Cost: $16,560 |
$2,027 | 42,228 | $3,522 | 199 | $83 | - | - | - |
$2,027 42,228 kWh |
$3,522 199 kW-months/year |
$83 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,392 Cost: $10,340 |
$1,583 | 32,972 | $2,744 | 155 | $65 | - | - | - |
$1,583 32,972 kWh |
$2,744 155 kW-months/year |
$65 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,329 Cost: $771 |
$1,309 | 27,284 | - | - | $20 | - | - | - |
$1,309 27,284 kWh |
- - kW-months/year |
$20 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,023 Cost: $7,463 |
$371 | 7,738 | $637 | 36 | $15 | - | - | - |
$371 7,738 kWh |
$637 36 kW-months/year |
$15 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $86,369 Cost: $423,245 |
$43,924 | 914,274 | $73,703 | 4,164 | $1,787 | - | $(-33,045) | - | $43,924 914,274 kWh |
$73,703 4,164 kW-months/year |
$1,787 - $ |
$(-33,045) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $27,537 Cost: $47,473 |
$10,753 | 223,190 | $16,355 | 924 | $429 | - | - | - | $10,753 223,190 kWh |
$16,355 924 kW-months/year |
$429 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes |