Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Mississippi State
Assessment Year 2024
Principal Product Aluminum Cylinders
NAICS 332999 - All Other Miscellaneous Fabricated Metal Product Manufacturing
SIC 3499 - Fabricated Metal Products, Nec
Sales $10,000,000-$50,000,000
# of Employees 120
Plant Area (Sq.Ft.) 210,000
Annual Production 2,293,000 Units
Production Hrs. Annual 4,160
Location (State) MS
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $481,015 10,596,449 kWh $0.05
Electricity Demand $340,032 24,372 kW-months/year $13.95
Electricity Fees $55,680 - $ -
Natural Gas $155,739 36,569 MMBtu $4.26
LPG $87,848 2,939 MMBtu $29.89
TOTAL ENERGY COSTS $1,122,236
RECOMMENDED SAVINGS* $286,290 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage LPG Electricity Usage LPG
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$10,241
Cost:
$17,637
$10,241 212,859 - - $10,241
212,859
kWh
-
-
MMBtu
02: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT Savings:
$79,176
Cost:
$275,000
$(-8,672) (-192,720) $87,848 2,939 $(-8,672)
(-192,720)
kWh
$87,848
2,939
MMBtu
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$3,155
Cost:
-
$3,155 70,121 - - $3,155
70,121
kWh
-
-
MMBtu
04: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$193,096
Cost:
$2,257,766
$193,096 3,176,285 - - $193,096
3,176,285
kWh
-
-
MMBtu
05: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$622
Cost:
$2,945
$622 13,833 - - $622
13,833
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$286,290
Cost:
$2,553,348
$198,442 3,280,377 $87,848 2,939 $198,442
3,280,377
kWh
$87,848
2,939
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage LPG Electricity Usage LPG